MétaCan
Menu
Back to cohort
Record W1561840099 · doi:10.1118/1.1350674

The effect of seed anisotropy on brachytherapy dose distributions using 125I and 103Pd

2001· article· en· W1561840099 on OpenAlexaff
Patricia Lindsay, Jerry Battista, Jake Van Dyk

Bibliographic record

VenueMedical Physics · 2001
Typearticle
Languageen
FieldPhysics and Astronomy
TopicAdvanced Radiotherapy Techniques
Canadian institutionsWestern University
Fundersnot available
KeywordsBrachytherapyDosimetryAnisotropyNuclear medicineMedical physicsDose rateMedical imagingPhysicsMedicineOpticsRadiologyRadiation therapy

Abstract

fetched live from OpenAlex

We have evaluated the effect of the anisotropy of individual seeds on dose distributions for permanent prostate implants using 125I and 103Pd. The dose distributions were calculated for various implants using both the line source and point source calculational formalisms, for two different models of 125I and 103Pd seeds. The dose distributions were compared using cumulative dose volume histograms (DVH) and cumulative difference dose volume histograms (deltaDVH) for the prostate target volume and for the rectum surface. The DVHs could not distinguish between the dose distributions from isotropic and non-isotropic seeds. However, the deltaDVHs were useful in determining the fraction of the target volume for which the difference between the dose distribution for line sources and for point sources exceeded a threshold value. The dose distributions were calculated (1) for all the seeds oriented co-linearly, along either the x-, y-, or z-axis, and (2) for the seeds at randomized orientations, more closely resembling the clinical situation. For all cases, there was a significant difference in the effect of seed anisotropy from the different seed types. For the geometrically simpler test cases with a small number of seeds, the effect of anisotropy on the dose distribution was too large to ignore for any of the seed types investigated. For the idealized pre-plan case, the effect was much smaller. For clinical prostate implants, the calculations done with seeds oriented co-linearly along the z-axis (needle implant axis) were a reasonable approximation for those from simulations of seeds with randomized orientations. Again, the effect of anisotropy varied drastically between different seed models, and also between different clinical cases. However, the effect of anisotropy must be considered in the context of all the other uncertainties in clinical brachytherapy treatments.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Other design · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.699
Threshold uncertainty score0.338

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.008
GPT teacher head0.299
Teacher spread0.291 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designOther design
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations19
Published2001
Admission routes1
Has abstractyes

Explore more

Same venueMedical PhysicsSame topicAdvanced Radiotherapy TechniquesFrench-language works237,207