MétaCan
Menu
Back to cohort
Record W1565481913 · doi:10.1002/jbm.a.34709

Performance of conical abutment (Morse Taper) connection implants: A systematic review

2013· review· en· W1565481913 on OpenAlexaff
Christian Schmitt, Getúlio da Rocha Nogueira Filho, Howard C. Tenenbaum, Jim Yuan Lai, Carlos Brito, Hendrik Döring, Jörg Nonhoff

Bibliographic record

VenueJournal of Biomedical Materials Research Part A · 2013
Typereview
Languageen
FieldDentistry
TopicDental Implant Techniques and Outcomes
Canadian institutionsUniversity of Toronto
Fundersnot available
KeywordsConical surfaceAbutmentImplantMaterials scienceDental AbutmentsOrthodonticsDentistryComputer scienceStructural engineeringMedicineComposite materialEngineeringSurgery

Abstract

fetched live from OpenAlex

In this systematic review, we aimed to compare conical versus nonconical implant-abutment connection systems in terms of their in vitro and in vivo performances. An electronic search was performed using PubMed, Embase, and Medline databases with the logical operators: "dental implant" AND "dental abutment" AND ("conical" OR "taper" OR "cone"). Names of the most common conical implant-abutment connection systems were used as additional key words to detect further data. The search was limited to articles published up to November 2012. Recent publications were also searched manually in order to find any relevant studies that might have been missed using the search criteria noted above. Fifty-two studies met the inclusion criteria and were included in this systematic review. As the data and methods, as well as types of implants used was so heterogeneous, this mitigated against the performance of meta-analysis. In vitro studies indicated that conical and nonconical abutments showed sufficient resistance to maximal bending forces and fatigue loading. However, conical abutments showed superiority in terms of seal performance, microgap formation, torque maintenance, and abutment stability. In vivo studies (human and animal) indicated that conical and nonconical systems are comparable in terms of implant success and survival rates with less marginal bone loss around conical connection implants in most cases. This review indicates that implant systems using a conical implant-abutment connection, provides better results in terms of abutment fit, stability, and seal performance. These design features could lead to improvements over time versus nonconical connection systems.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.010
metaresearch head score (Gemma)0.033
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Systematic review · Consensus signal: Systematic review
GenreCandidate signal: Review · Consensus signal: Review
Teacher disagreement score0.013
Threshold uncertainty score0.054

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0100.033
Meta-epidemiology (narrow)0.0020.001
Meta-epidemiology (broad)0.0100.009
Bibliometrics0.0130.012
Science and technology studies0.0010.001
Scholarly communication0.0030.003
Open science0.0020.001
Research integrity0.0020.001
Insufficient payload (model declined to judge)0.0030.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.155
GPT teacher head0.470
Teacher spread0.315 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designSystematic review
Domainnot available
GenreReview

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations260
Published2013
Admission routes1
Has abstractyes

Explore more

Same venueJournal of Biomedical Materials Research Part ASame topicDental Implant Techniques and OutcomesFrench-language works237,207