MétaCan
Menu
Back to cohort
Record W1573935620

Drug Delivery to the Posterior Eye Using Etched Microneedles

2011· dissertation· en· W1573935620 on OpenAlexfundno aff
Geetha Mahadevan

Bibliographic record

VenueMacSphere (McMaster University) · 2011
Typedissertation
Languageen
FieldPharmacology, Toxicology and Pharmaceutics
TopicAdvancements in Transdermal Drug Delivery
Canadian institutionsnot available
FundersNatural Sciences and Engineering Research Council of Canada
KeywordsDrug deliveryOphthalmologyOptometryMedicineBiomedical engineeringMaterials scienceNanotechnology
DOInot available

Abstract

fetched live from OpenAlex

Sight-threatening diseases, such as age-related macular degeneration (AMD), affect the tissues of the posterior segment of the eye. Though modern classes of biomolecular based drugs are therapeutically useful, drug targeting for prolonged bioavailability to pathological sites within the eye is challenging. Current delivery approaches are invasive and lack control over drug release rates and tissue-specific localization. In this thesis, a device using microneedles embedded in a flexible platform was developed that could potentially overcome these challenges. New methods for microneedle fabrication were developed by co-opting simple chemical etch methods commonly used for optical probe fabrication as an alternative to current complex and expensive photolithographic technologies to produce out-of-plane, high aspect ratio microneedles which are often constrained materially to silicon and metal. Microneedles with repeatable tip and taper sizes were obtained using hydrofluoric acid, an organic phase and fused-silica capillary tubing. Microneedles with 10 um tips were made using single and batch mode methods and were then integrated into poly (dimethylsiloxane) (PDMS) for alignment using low cost micromolding approaches offering the same degree of accuracy provided by conventional photolithography<strong>. </strong> Single microneedle-based devices successfully delivered rhodamine intrasclerally, intravitreally, suprachoroidally and to the retina. This is the first demonstration of active delivery to specific spatial regions within the posterior eye at controllable rates using a non-implantable, biocompatible device – with minimal fabrication facilities, equipment and cost. The fabricated device demonstrated a new hybrid approach of coupling a rigid microneedle with a soft and pliable substrate that could conform to biological tissues.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMeta-epidemiology (narrow), Insufficient payload (model declined to judge)
Consensus categoriesInsufficient payload (model declined to judge)
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Not applicable · Consensus signal: none
GenreCandidate signal: Other · Consensus signal: none
Teacher disagreement score0.953
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.001
Science and technology studies0.0010.000
Scholarly communication0.0000.000
Open science0.0010.000
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.1030.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.063
GPT teacher head0.339
Teacher spread0.275 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; both teacher heads agree on what is shown here.

Study designNot applicable
Domainnot available
GenreOther

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2011
Admission routes1
Has abstractyes

Explore more

Same venueMacSphere (McMaster University)Same topicAdvancements in Transdermal Drug DeliveryFrench-language works237,207