MétaCan
Menu
Back to cohort
Record W1574320938 · doi:10.1115/imece2014-37794

Evaluation of Passive Anti-Fouling Technology Applied to CO2 Heat Pump Water Heaters

2014· article· en· W1574320938 on OpenAlexaff
Portia Murray, S. J. Harrison, Ben Stinson

Bibliographic record

Venuenot available
Typearticle
Languageen
FieldEngineering
TopicRefrigeration and Air Conditioning Technologies
Canadian institutionsParteq Innovations (Canada)Queen's University
Fundersnot available
KeywordsFoulingThermosiphonEnvironmental scienceHeat transferHeat pumpWaste managementWater coolingHeat exchangerEnvironmental engineeringMaterials sciencePetroleum engineeringChemistryMechanicsMechanical engineeringEngineering

Abstract

fetched live from OpenAlex

Heat pump water heaters are increasing in popularity due to their increased energy efficiency and low environmental impact. This paper describes the experimental testing of a transcritical CO2 heat pump water heater at Queen’s University. A modified 4.5 kW Eco-Cute unit was studied. It sourced heat from a constant temperature water supply and rejected the heat to a 273 litre hot water tank through a gas-cooler. The high temperatures that occur in the gas-cooler of this unit make it ideally suited for natural convection, (i.e., thermosyphon) circulation on the potable water side. This has the potential to reduce pumping power, simplify system operation and design, and increase thermal stratification in the hot water storage tank. This configuration, however, is susceptible to the accumulation of sediments, scale and mineral deposits (i.e., fouling) in geographic regions where high mineral deposits may be present in the water supply. To counteract fouling in these cases, a passive back-flushing system was proposed to prevent the accumulation of deposits on the heat transfer surfaces of the gas-cooler. As hot water is drawn from the system, the cold “mains” supply water is directed through the gas-cooler in the reverse direction of normal operation, scouring the heat transfer surfaces and dissolving deposits of inverse-soluble salts which are a major contributor to fouling on hot heat transfer surfaces. The gas-cooler used was a specially designed unit that, although offering high performance in a compact unit, may be susceptible to the fouling and blockage of the heat transfer passages when used at thermosyphon flow rates. Experiments were conducted to evaluate the effects of the back-flush operation on heat pump performance (i.e., COP) and operation. These were conducted under controlled laboratory conditions, at a range of draw flow rates and temperatures, and are summarized in this paper.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.243
Threshold uncertainty score0.295

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.012
GPT teacher head0.231
Teacher spread0.219 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2014
Admission routes1
Has abstractyes

Explore more

Same topicRefrigeration and Air Conditioning TechnologiesFrench-language works237,207