Estudio del proceso de absorción con amoniaco-agua en intercambiadores de placas para equipos de refrigeración por absorción.
Why this work is in the frame
A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.
Bibliographic record
Abstract
En los ultimos anos ha aumentado la demanda de equipos de refrigeracion por absorcion de pequena potencia con accionamiento termico a baja temperatura. El desarrollo de estos equipos requiere altas prestaciones en los procesos de transferencia de calor y de materia en los componentes mas criticos: absorbedor, generador y rectificador. Este trabajo forma parte del proyecto de investigacion Desarrollo de componentes avanzados para el diseno y fabricacion de maquinas de refrigeracion por absorcion con NH3-H2O de pequena potencia y activacion termica a baja temperatura, coordinado por el Centro de Innovacion Tecnologica CREVER de la URV y subvencionado por el Plan Nacional de I&D del Ministerio de Ciencia y Tecnologia. Esta tesis esta dedicada al estudio teorico-experimental del proceso de absorcion en burbujas en un intercambiador de calor de placas utilizando la mezcla amoniaco-agua. En primer lugar se ha desarrollado un modelo de un absorbedor de burbujas unidimensional basado en la discretizacion de un intercambiador de placas corrugadas de tres canales, en cuyo canal central tiene lugar la absorcion. La formulacion matematica del modelo se basa en los balances de materia y energia para cada volumen de control, las ecuaciones de transferencia de calor y masa, asi como consideraciones de equilibrio. Los coeficientes de transferencia y otros parametros fisicos del modelo han sido estimados a partir de correlaciones empiricas de la bibliografia. La simulacion proporciona, entre otros resultados, los perfiles longitudinales de la temperatura, concentracion de la disolucion y caudal masico de cada corriente, el flujo de vapor absorbido y la carga termica del absorbedor. Ademas se realiza una comparacion de las predicciones del modelo con los obtenidos para la mezcla NH3-LiNO3. El interes de esta mezcla es que su uso no requiere la rectificacion de los vapores despues del generador y permite asimismo reducir la temperatura de la fuente de calor de accionamiento. Para llevar a cabo el estudio experimental se ha disenado y construido un banco de ensayos que permite caracterizar el absorbedor en distintas condiciones de operacion y configuraciones de flujo, y generar una base de datos experimentales. Los ensayos fueron realizados en un intercambiador de placas corrugadas tipo L, Alfa Laval modelo NB51, de tres canales. Las condiciones de los ensayos son: presion del absorbedor de unos 2 bar, temperatura de absorcion entre 32.4 y 38.4oC, concentraciones masicas en NH3 de la solucion a la entrada entre 29 y 33%, y diferentes condiciones termicas de la solucion a la entrada. Los resultados obtenidos en las distintas experiencias para el flujo de absorcion se situan entre 0.002 y 0.007 kg/m2 s, el coeficiente de transferencia de calor de la solucion entre 2.7 y 6.8 kW/m2 K, la carga termica del absorbedor entre 0.46 y 1.32 kW, y la eficiencia masica del absorbedor entre 0.30 y 0.62. La base de datos experimentales obtenida ha permitido establecer la capacidad predictiva del modelo elaborado. A pesar de su simplicidad, el modelo es capaz de interpretar correctamente la influencia de las distintas variables sobre los parametros de eficacia del absorbedor, si bien las desviaciones en los resultados para el flujo de absorcion y la carga termica del absorbedor pueden llegar al 50%. La capacidad predictiva del modelo podra mejorarse si se adoptan correlaciones para los coeficientes de transferencia, especificas al fluido de trabajo y de configuracion de flujos. Basandose en los datos experimentales del coeficiente de transferencia de calor y del flujo de absorcion obtenidos en el presente trabajo, se ha realizado el diseno preliminar de un absorbedor de burbujas utilizando un intercambiador de placas para un equipo de refrigeracion por absorcion de NH3-H2O de 6 kW. SUMMARY The interest in low capacity absorption chillers driven by low temperature heat sources has increased in the last years. The development of these machines requires high efficiencies of heat and mass transfer processes taking place in the main components, namely, the absorber, generator, and rectifier. This work was carried out in the framework of a research project entitled Development of advanced component for the design and manufacturing of low capacity absorption refrigeration machines with NH3-H2O, funded by the Spanish Ministry of Science and Technology. The subject of this thesis deals with a theoretical and experimental study of the bubble absorption process in a plate heat exchanger using the working fluid ammonia-water. A one-dimensional model of a bubble absorber was developed, based on the discretization of a corrugated plate heat exchanger of three channels, where absorption takes place in the central one. The mathematical formulation is based on heat and mass balances, heat and mass transfer equations, as well as equilibrium conditions for each control volume. Heat and mass transfer coefficients and other physical parameters of the model were estimated from empirical correlations available in the open literature. The results provide mainly longitudinal profiles of temperature, concentration and flow rate of each stream, vapor absorption rate, and absorber thermal load. Besides, a comparison of the model predictions was performed for the working fluid NH3-LiNO3, which permits to eliminate rectification in the absorption machine and decrease the heat source temperature. An experimental test bench was layout and set-up to characterize the real behavior of the absorber at different operating conditions and flow configurations, and to generate an experimental database of the absorption process. Experiments were carried out using a corrugated plate heat exchanger with three channels (model NB51, type L), provided by Alfa Laval. The operating conditions considered were: absorber pressure about 2 bar, absorption temperature range from 32.4 to 38.4 °C, inlet solution mass concentration from 29 to 33 %, and different temperatures of the solution entering the absorber. The results achieved for the absorption flux were in the range 0.002 - 0.007 kg/m2 s, the solution heat transfer coefficient varied between 2.7 and 6.8 kW/m2 K, the absorber thermal load from 0.46 to 1.32 kW, while the absorber mass efficiency was in the range 0.30 - 0.62. The experimental data were used to evaluate the predictive capacity of the theoretical model developed. In spite of its simplicity, the model is able to well interpret the effect of the different operation variables on the absorber performance parameters; though the deviation in the results for absorption flux and absorber thermal load can reach 50%. The predictive capacity of the model can be improved if the correlations used for heat and mass transfer coefficients are specific for the working fluid and flow configuration. Using the experimental data achieved in this work for heat transfer coefficient and absorption flux, a preliminary thermal design of a bubble absorber with a plate heat exchanger was performed for a 6 kW ammonia-water absorption chiller.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
Full frame distilled prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.
Codex and Gemma teacher scores by category
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.001 | 0.001 |
| Meta-epidemiology (narrow) | 0.002 | 0.002 |
| Meta-epidemiology (broad) | 0.002 | 0.001 |
| Bibliometrics | 0.001 | 0.001 |
| Science and technology studies | 0.001 | 0.000 |
| Scholarly communication | 0.001 | 0.001 |
| Open science | 0.001 | 0.000 |
| Research integrity | 0.002 | 0.002 |
| Insufficient payload (model declined to judge) | 0.001 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it