MétaCan
Menu
Back to cohort
Record W1576153523 · doi:10.1093/jaoac/85.2.470

Method Extension Study to Validate Applicability of AOAC Official Method 997.03 Visual Immunoprecipitate Assay (VIP®) for Listeria monocytogenes and Related Listeria spp. from Environmental Surfaces: Collaborative Study

2002· article· en· W1576153523 on OpenAlexaboutno aff
Philip T Feldsine, Andrew H Lienau, Stephanie Leung, Linda A Mui, Gustavo Aguilar, J Aharchi, I Aldridge, V Arling, Benjamin F. Bitner, C. Michael Bullard, Paul J. Carlson, Charles D. Cox, K Deiss, John Dillon, P Dombroski, Jay L.E. Ellingson, Shane Fitzgerald, Robin L Forgey, K Gailbreath, Daniel L. Gallagher, V Geftman, K Herbst, P Hillis, M. C. Johnson, Stephen A. Koch, Dyani Lewis, J Luepke, D Martensen, S McDonagh, B McGovern, B Moon, Larry W. Moreland, Lyndsay M. Murray, Daniel S. Richter, M.J. Robertson, Phil Rogers, C. Wilbur Rucker, J Sacca, C. Smith, J. E. Smith, E Stoltzfus, Cliff H. Summers, Barry R. Taylor, J. Tóth, Robert W. Vess, S. White, J-L Witt, Savannah S. Young

Bibliographic record

VenueJournal of AOAC International · 2002
Typearticle
Languageen
FieldBiochemistry, Genetics and Molecular Biology
TopicListeria monocytogenes in Food Safety
Canadian institutionsnot available
Fundersnot available
KeywordsListeria monocytogenesListeriaExtension (predicate logic)ChemistryFood scienceBiologyComputer scienceBacteriaGenetics

Abstract

fetched live from OpenAlex

Test portions from 3 environmental surface types, representative of typical surfaces found in a food production facility, were analyzed by the Visual Immunoprecipitate assay (VIP) and the U.S. Department of Agriculture/Food Safety and Inspection Service (USDA/FSIS) culture method for Listeria monocytogenes and related Listeria species. In all cases, naturally contaminated environmental test samples were collected from an actual food production facility by sponge or swab. Test samples from concrete surfaces were collected by both swab and sponge; sponge test samples were collected from rubber surfaces, and swabs were used to sample steel surfaces. Test portions from each surface type were simultaneously analyzed by both methods. A total of 27 laboratories, representing government agencies as well as private industry in both the United States and Canada, participated in the study. During this study, a total of 615 test portions and controls was analyzed and confirmed, of which 227 were positive and 378 were negative by both methods. Nine test portions were positive by culture, but negative by the VIP. Five test portions were negative by culture, but positive by the VIP. Four test portions were negative by VIP and by culture, but confirmed positive when VIP enrichment broths were subcultured to selective agars. The data reported here indicate that the VIP method and the USDA/FSIS culture method are statistically equivalent for detection of L. monocytogenes and related Listeria species from environmental surfaces taken by sponges or swabs.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.055
metaresearch head score (Gemma)0.040
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Methods · Consensus signal: none
Teacher disagreement score0.055
Threshold uncertainty score0.289

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0550.040
Meta-epidemiology (narrow)0.0020.001
Meta-epidemiology (broad)0.0010.002
Bibliometrics0.0020.002
Science and technology studies0.0020.001
Scholarly communication0.0020.001
Open science0.0020.003
Research integrity0.0020.001
Insufficient payload (model declined to judge)0.0020.002

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.052
GPT teacher head0.378
Teacher spread0.326 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreMethods

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations4
Published2002
Admission routes1
Has abstractyes

Explore more

Same venueJournal of AOAC InternationalSame topicListeria monocytogenes in Food SafetyFrench-language works237,207