MétaCan
Menu
Back to cohort
Record W1576344792 · doi:10.1159/000106029

Image Guidance: Treatment Target Localization Systems

2007· review· en· W1576344792 on OpenAlexaff
Michael B. Sharpe, Tim Craig, D Moseley

Bibliographic record

VenueFrontiers of radiation therapy and oncology · 2007
Typereview
Languageen
FieldPhysics and Astronomy
TopicAdvanced Radiotherapy Techniques
Canadian institutionsPrincess Margaret Cancer CentreUniversity of Toronto
Fundersnot available
KeywordsComputer visionMedical physicsComputer sciencePosition (finance)MedicineRadiation therapyQuality assuranceArtificial intelligenceRadiologyPathology

Abstract

fetched live from OpenAlex

Highly conformal radiation therapy tailors treatment to match the target shape and position, minimizing normal tissue damage to a greater extent than previously possible. Technological advances such as intensity-modulated radiation therapy, introduced a decade ago, have yielded significant gains in tumor control and reduced toxicity. Continuing advances have focused on the characterization and control of patient movement, organ motion, and anatomical deformation, which all introduce geometric uncertainty. These sources of uncertainty limit the effectiveness of high-precision treatment. Target localization, performed using appropriate technologies and frequency, is a critical component of treatment quality assurance. Until recently, the target position with respect to the beams has been inferred from surface marks on the patient's skin or through an immobilization device, and verified using megavoltage radiographs of the treatment portal. Advances in imaging technologies have made it possible to image soft tissue volumes in the treatment setting. Real-time tracking is also possible using a variety of technologies, including fluoroscopic imaging and radiopaque markers implanted in or near the tumor. The capacity to acquire volumetric soft tissue images in the treatment setting can also be used to assess anatomical changes over a course of treatment. Enhancing localization practices reduces treatment errors, and gives the capacity to monitor anatomical changes and reduce uncertainties that could influence clinical outcomes. This review presents the technologies available for target localization, and discusses some of the considerations that should be addressed in the implementation of many new clinical processes in radiation oncology.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Not applicable · Consensus signal: none
GenreCandidate signal: Review · Consensus signal: Review
Teacher disagreement score0.007
Threshold uncertainty score0.025

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0020.002
Science and technology studies0.0000.001
Scholarly communication0.0010.001
Open science0.0020.001
Research integrity0.0020.001
Insufficient payload (model declined to judge)0.0070.009

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.025
GPT teacher head0.347
Teacher spread0.322 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designNot applicable
Domainnot available
GenreReview

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations11
Published2007
Admission routes1
Has abstractyes

Explore more

Same venueFrontiers of radiation therapy and oncologySame topicAdvanced Radiotherapy TechniquesFrench-language works237,207