MétaCan
Menu
← Back to cohort

Abutment Rotational Freedom Evaluation of External Hexagon Single‐Implant Restorations after Mechanical Cycling

2012· article· en· W1578895052 on OpenAlexvenueno aff
Marcela Caffarena Junqueira, Thales Eduardo P. Silva, Ricardo Faria Ribeiro, Adriana Cláudia Lapria Faria, Ana Paula Macedo, Rossana Pereira de Almeida Antunes

Bibliographic record

VenueClinical Implant Dentistry and Related Research · 2012
Typearticle
Languageen
FieldDentistry
TopicDental Implant Techniques and Outcomes
Canadian institutionsnot available
FundersCoordenação de Aperfeiçoamento de Pessoal de Nível Superior
KeywordsAbutmentMaterials scienceImplantCastingDental AbutmentsDentistryOrthodonticsCyclingComposite materialStructural engineeringMedicineEngineeringSurgery

Abstract

fetched live from OpenAlex

PURPOSE: The purpose of this study was to evaluate the rotational freedom between implant and abutment counterpart of two abutments types over external hexagon implants submitted to mechanical cycling. MATERIALS AND METHODS: Ten implants with external hexagon (3.75 mm × 13 mm), five cast abutments, and five premachined abutments both with 4.1 mm plataform size were used in this study. Ten metallic crowns were fabricated using the two types of abutments and were fixed to each implant using titanium screws (Ti6Al4V). Rotational freedom measurements were made before and after the cast procedure and after the mechanical cycling. Groups were classified according to the rotational misfit register using University of California, Los Angeles abutment and implants as new (group 1 = G1); using crowns and implants after crown casting (group 2 = G2); and using crowns and implants after mechanical cycling (group 3 = G3). Oblique loading of 120N at 1.8 Hz and 5 × 10(5) cycles was applied on specimen. RESULTS: Statistical analysis (p < .05) showed that no significant difference was observed when cast abutment was compared with premachined abutment after casting (p = .390) and mechanical cycling (p = .439); however, significant difference was noted before the casting (p = .005) with higher values for the cast abutments. CONCLUSIONS: Within the limitations of this in vitro study, it could be concluded that the abutment type used do not influenced the rotational freedom after casting and the amount of applied cycles (500,000 cycles) was not sufficient to significantly alter the values of rotational freedom at the implant/abutment joint.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.001
Threshold uncertainty score0.004

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.245
GPT teacher head0.498
Teacher spread0.253 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations10
Published2012
Admission routes1
Has abstractyes

Explore more

Same venueClinical Implant Dentistry and Related Research→Same topicDental Implant Techniques and Outcomes→French-language works237,207→