MétaCan
Menu
Back to cohort
Record W1580683005 · doi:10.1155/2012/782790

Indicators of Safety Compromise in Gastrointestinal Endoscopy

2012· review· en· W1580683005 on OpenAlexafffundvenueabout
Mark Borgaonkar, Lawrence Hookey, Roger Hollingworth, Ernst J. Kuipers, Alan J. Forster, David Armstrong, Alan Barkun, Ronald Bridges, Rose Carter, Chris de Gara, Catherine Dubé, Robert Enns, Donald MacIntosh, Sylviane Forget, Grigorios I. Leontiadis, Jonathan B. Meddings, Peter B. Cotton, Roland Valori

Bibliographic record

VenueCanadian Journal of Gastroenterology · 2012
Typereview
Languageen
FieldImmunology and Microbiology
TopicMedical Device Sterilization and Disinfection
Canadian institutionsDalhousie UniversityUniversity of British ColumbiaUniversity of AlbertaUniversity of CalgaryMcGill UniversityUniversity of OttawaCredit Valley HospitalCanadian Association of GastroenterologyMcMaster UniversityQueen's UniversityMemorial University of Newfoundland
FundersCanadian Institutes of Health Research
KeywordsMedicineEndoscopyPatient safetyCompromiseHarmQuality (philosophy)Identification (biology)Health careSurgeryPsychology

Abstract

fetched live from OpenAlex

The growth in the use of endoscopy to diagnose and treat many gastointestinal disorders, and its central role in cancer screening programs, has led to a significant increase in the number of procedures performed. This growth, however, has also led to many variations in, among others, the provision of services, the choice of sedative medications and the training of providers. The recognition of the significance of quality in endoscopy has prompted several countries, including Canada, to initiate efforts to adopt nationwide quality improvement programs. The Canadian Association of Gastroenterology formed a committee to review endoscopy and quality with the aim of stimulating improvement. This article focuses specifically on patient safety indicators that were developed at a consensus conference aimed at generating a broad range of recommendations for selected endoscopic procedures, which if adopted, could lead to significant changes in how endoscopy services are provided. INTRODUCTION: The importance of quality indicators has become increasingly recognized in gastrointestinal endoscopy. Patient safety requires the identification and monitoring of occurrences associated with harm or the potential for harm. The identification of relevant indicators of safety compromise is, therefore, a critical element that is key to the effective implementation of endoscopy quality improvement programs. OBJECTIVE: To identify key indicators of safety compromise in gastrointestinal endoscopy. METHODS: The Canadian Association of Gastroenterology Safety and Quality Indicators in Endoscopy Consensus Group was formed to address issues of quality in endoscopy. A subcommittee was formed to identify key safety indicators. A systematic literature review was undertaken, and articles pertinent to safety in endoscopy were identified and reviewed. All complications and measures used to document safety were recorded. From this, a preliminary list of 16 indicators was compiled and presented to the 35-person consensus group during a three-day meeting. A revised list of 20 items was subsequently put to the consensus group for vote for inclusion on the final list of safety indicators. Items were retained only if the consensus group highly agreed on their importance. RESULTS: A total of 19 indicators of safety compromise were retained and grouped into the three following categories: medication-related – the need for CPR, use of reversal agents, hypoxia, hypotension, hypertension, sedation doses in patients older than 70 years of age, allergic reactions and laryngospasm/bronchospasm; procedure-related early – perforation, immediate postpolypectomy bleeding, need for hospital admission or transfer to emergency department from the gastroenterology unit, instrument impaction, severe persistent abdominal pain requiring evaluation proven to not be perforation; and procedure-related delayed – death within 30 days of procedure, 14-day unplanned hospitalization, 14-day unplanned contact with a health provider, gastrointestinal bleeding within 14 days of procedure, infection or symptomatic metabolic complications. CONCLUSIONS: The 19 indicators of safety compromise in endoscopy, identified by a rigorous, evidence-based consensus process, provide clear outcomes to be recorded by all facilities as part of their continuing quality improvement programs.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.082
metaresearch head score (Gemma)0.209
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Systematic review · Consensus signal: none
GenreCandidate signal: Review · Consensus signal: Review
Teacher disagreement score0.082
Threshold uncertainty score0.434

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0820.209
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0030.003
Bibliometrics0.0260.027
Science and technology studies0.0010.002
Scholarly communication0.0040.005
Open science0.0020.003
Research integrity0.0020.002
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.023
GPT teacher head0.272
Teacher spread0.249 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designSystematic review
Domainnot available
GenreReview

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations22
Published2012
Admission routes4
Has abstractyes

Explore more

Same venueCanadian Journal of GastroenterologySame topicMedical Device Sterilization and DisinfectionFrench-language works237,207