MétaCan
Menu
Back to cohort
Record W1592199073 · doi:10.1002/ccd.25131

Five‐year clinical follow‐up of a randomized comparison of a polymer‐free sirolimus‐eluting stent versus a polymer‐based paclitaxel‐eluting stent in patients with diabetes mellitus (LIPSIA Yukon trial)

2013· article· en· W1592199073 on OpenAlexaboutno aff
Thomas Stiermaier, Anja Heinz, Denis Schloma, Klaus Kleinertz, Wilfried Dänschel, Sandra Erbs, Axel Linke, Enno Boudriot, Bernward Lauer, Gerhard Schüler, Hölger Thiele, Steffen Desch

Bibliographic record

VenueCatheterization and Cardiovascular Interventions · 2013
Typearticle
Languageen
FieldMedicine
TopicCoronary Interventions and Diagnostics
Canadian institutionsnot available
Fundersnot available
KeywordsMedicineStentSirolimusMyocardial infarctionSurgeryRandomized controlled trialRestenosisTarget lesionInternal medicineRevascularizationDiabetes mellitusMaceClinical endpointCardiologyPercutaneous coronary intervention

Abstract

fetched live from OpenAlex

OBJECTIVES: The long-term performance of polymer-free stent systems in patients with diabetes mellitus has not been investigated extensively. This study reports long-term results of the LIPSIA Yukon trial which compared the polymer-free sirolimus-eluting Yukon Choice stent with the polymer-based paclitaxel-eluting Taxus Liberté stent in this subpopulation. At 9 months, the Yukon Choice stent failed to show non-inferiority in terms of the primary end point late lumen loss, while no significant difference in clinical outcome was detected. METHODS AND RESULTS: The LIPSIA Yukon trial randomized 240 patients with diabetes mellitus to a polymer-free sirolimus eluting stent (Yukon Choice, Translumina) versus a polymer-based paclitaxel-eluting stent (Taxus Liberté, Boston Scientific). Clinical follow-up was conducted with a standardized telephone follow-up and all events were centrally adjudicated. Follow-up was available for 98.3% of patients after a median of 5.0 years. The incidence of all-cause death (16.9% versus 14.0%, P = 0.67), respectively definite or presumed cardiovascular death (7.6% versus 8.8%, P = 0.94) were similar in the Yukon Choice and the Taxus Liberté group. There were no significant differences in the rates of myocardial infarction (9.3% versus 7.9%, P = 0.88), definite stent thrombosis (0.8% versus 0.9%, P = 1.0), target lesion revascularization (15.3% versus 15.8%, P = 1.0), target vessel revascularization (18.6% versus 23.7%, P = 0.44), non-target vessel revascularization (18.6% versus 26.3%, P = 0.21), and stroke (3.4% versus 4.4%, P = 0.96) between patients assigned to the Yukon Choice and the Taxus Liberté stent. CONCLUSION: At 5 years of follow-up, clinical outcome was similar between the polymer-free sirolimus-eluting Yukon Choice stent and the polymer-based paclitaxel-eluting Taxus Liberté stent.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Randomized trial · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.634
Threshold uncertainty score0.898

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0020.003
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.037
GPT teacher head0.302
Teacher spread0.265 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designRandomized trial
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations26
Published2013
Admission routes1
Has abstractyes

Explore more

Same venueCatheterization and Cardiovascular InterventionsSame topicCoronary Interventions and DiagnosticsFrench-language works237,207