MétaCan
Menu
Back to cohort

Right Atrial Size Relates to Right Ventricular End-Diastolic Pressure in an Adult Population with Congenital Heart Disease

2010· article· en· W1595453803 on OpenAlexaff
Doan Hoa, Judith Therrien, Ariane Marelli, Giuseppe Martucci, Jonathan Afilalo, Igal A. Sebag

Bibliographic record

VenueEchocardiography · 2010
Typearticle
Languageen
FieldMedicine
TopicPulmonary Hypertension Research and Treatments
Canadian institutionsMcGill UniversityJewish General HospitalCentre Hospitalier Universitaire de SherbrookeMcGill University Health CentreUniversité de Sherbrooke
Fundersnot available
KeywordsCardiologyInternal medicineMedicineDiastoleReproducibilityPopulationHeart diseaseCardiac catheterizationRight heartBlood pressureChemistry

Abstract

fetched live from OpenAlex

AIM: Noninvasive markers of right ventricular (RV) diastolic dysfunction are limited by their lack of reproducibility and accuracy. We tested the hypothesis that right atrial (RA) size measured by echocardiography was correlated to invasive parameters of RV diastolic filling. METHODS AND RESULTS: We studied 31 consecutive adult patients with congenital heart disease. From 2D echocardiography images, we measured maximal RA long-axis and short-axis lengths, area and volume. We compared each of these measures to right ventricular end-diastolic pressure (RVEDP) and mean right atrial pressure (mRAP) measured by right heart catheterization. RA long-axis, short-axis, area, and volume correlated significantly with RVEDP (r = 0.78, P < 0.001; r = 0.61, P < 0.001; r = 0.79, P < 0.001; and r = 0.75, P < 0.001, respectively) and mRAP (r = 0.66, P < 0.001; r = 0.56, P = 0.002; r = 0.70, P < 0.001; r = 0.68, P < 0.001, respectively). Single cut points for each echocardiographic parameter demonstrated reasonable accuracy to rule-in and rule-out RVEDP ≥ 7 mm Hg (sensitivity = 74%, specificity = 82%, positive LR = 4.1, negative LR = 0.32 for RA long-axis of 49 mm; sensitivity = 89%, specificity = 82%, positive LR = 4.9, negative LR = 0.12 for RA area of 14 cm²; sensitivity = 89%, specificity = 82%, positive LR = 4.9, negative LR = 0.13 for RA volume of 37 mL). CONCLUSION: RA size measured by echocardiography is strongly correlated to invasive parameters of RV diastolic filling and predicts high RV end-diastolic pressure.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.004
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.001
Threshold uncertainty score0.004

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.004
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.000
Science and technology studies0.0000.000
Scholarly communication0.0000.001
Open science0.0000.000
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.006
GPT teacher head0.249
Teacher spread0.243 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations32
Published2010
Admission routes1
Has abstractyes

Explore more

Same venueEchocardiographySame topicPulmonary Hypertension Research and TreatmentsFrench-language works237,207