MétaCan
Menu
← Back to cohort
Record W160273714 · doi:10.3390/curroncol13020005

Intensity Modulated and Three-Dimensional Conformal Radiation Therapy Plans for Oropharyngeal Cancer: A Comparison of Their Sensitivity to Set-Up Errors and Uncertainties

2006· article· en· W160273714 on OpenAlexaffvenueabout
Nicolas Ploquin, Harold Lau, Peter Dunscombe

Bibliographic record

VenueCurrent Oncology · 2006
Typearticle
Languageen
FieldPhysics and Astronomy
TopicAdvanced Radiotherapy Techniques
Canadian institutionsUniversity of Calgary
Fundersnot available
KeywordsMedicineNuclear medicineRadiation therapyMonte Carlo methodStandard deviationSensitivity (control systems)Set (abstract data type)Radiation treatment planningMedical physicsHead and neck cancerStatisticsMathematicsComputer scienceRadiology

Abstract

fetched live from OpenAlex

We compared the effect of set-up error and uncertainty on two radiation therapy treatment plans for head and neck cancer: one using intensity modulated radiation therapy (IMRT) and one using conventional three-dimensional conformal radiation therapy (3D-CRT). We used a Pinnacle3 (Philips Medical Systems, Markham, Ontario) system to create the two treatment plans (7-beam IMRT and 5-beam 3D-CRT) for the same volumetric data set, based on the objectives and constraints defined in the Radiation Therapy Oncology Group H-0022 protocol. In both plans, the dose-volume constraints for the targets and the organs at risk (oars) were met as closely as the beam geometries would allow. Monte Carlo-based simulations of set-up error and uncertainty were performed in three orthogonal directions for 840 simulated "courses of treatment" for each plan. A systematic error (chosen from distributions characterized by standard deviations ranging from 0 mm to 6 mm) and random uncertainties (2 mm standard deviation) were incorporated. We used a probability approach to compare the sensitivities of the IMRT and the 3D-CRT plans to set-up error and uncertainty in terms of equivalent uniform dose (EUD) to targets and oars.Based on the EUD analysis, the targets and oars showed considerably greater sensitivity to set-up error with the IMRT plan than with the 3D-CRT plan. For the IMRT plan, target EUDS were reduced by 4%, 7.5%, and 10% for 2-mm, 4-mm, and 6-mm set-up errors respectively. However, even with set-up error, the mandible, spinal cord, and parotid EUDS always remained lower with the IMRT plan than with the 3D-CRT plan.We conclude that, when quantified by EUD, IMRT-plan doses to oars and targets are more sensitive to set-up error than are 3D-CRT-plan doses. However, as judged by the differences between target and OAR doses, IMRT retains its superiority over 3D-CRT, even in the presence of set-up error.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.005
metaresearch head score (Gemma)0.030
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.005
Threshold uncertainty score0.027

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0050.030
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0010.001
Science and technology studies0.0000.001
Scholarly communication0.0010.000
Open science0.0010.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.054
GPT teacher head0.379
Teacher spread0.324 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations8
Published2006
Admission routes3
Has abstractyes

Explore more

Same venueCurrent Oncology→Same topicAdvanced Radiotherapy Techniques→French-language works237,207→