MétaCan
Menu
Back to cohort
Record W1605550215 · doi:10.1002/jmri.24987

Classifying CT/MR findings in patients with suspicion of hepatocellular carcinoma: Comparison of liver imaging reporting and data system and criteria‐free Likert scale reporting models

2015· article· en· W1605550215 on OpenAlexfundno aff
Yu‐Dong Zhang, Xun Xu, Qing Wang, Chen‐Jiang Wu, Xi‐Sheng Liu, Hai‐Bin Shi

Bibliographic record

VenueJournal of Magnetic Resonance Imaging · 2015
Typearticle
Languageen
FieldMedicine
TopicHepatocellular Carcinoma Treatment and Prognosis
Canadian institutionsnot available
FundersNational Natural Science Foundation of ChinaYork University
KeywordsMedicineHepatocellular carcinomaMagnetic resonance imagingRadiologyIntraclass correlationNuclear medicineKappaLogistic regressionInternal medicine

Abstract

fetched live from OpenAlex

PURPOSE: To compare the Liver Imaging Reporting and Data System (LI-RADS) and a criteria-free Likert scale (LS) reporting models for classifying computed tomography/magnetic resonance imaging (CT/MR) findings of suspicious hepatocellular carcinoma (HCC). MATERIALS AND METHODS: Imaging data of 281 hepatic nodules in 203 patients were retrospectively included. Imaging characteristics including diameter, arterial hyperenhancement, washout, and capsule were reviewed independently by two groups of readers using LI-RADS and LS (range, score 1-5). LS is primarily based on the overall impression of image findings without using fixed criteria. Interreader agreement (IRA), intraclass agreement (ICA), and diagnostic performance were determined by Fleiss, Cohen's kappa (κ), and logistic regression, respectively. RESULTS: There were 167 contrast-enhanced CT (CECT) versus 114 MR data. Overall, IRA was moderate (κ = 0.47, 0.52); IRA was moderate-to-good for arterial hyperenhancement, washout, and capsule (κ = 0.56-0.69); excellent for diameter and tumor embolus (κ = 0.99). Overall, ICA between LI-RADS and LS was moderate (κ = 0.44-0.50); ICA was good for scores 1-2 (κ = 0.71-0.90), moderate for scores 3 and 5 (κ = 0.41-0.52), but very poor for score 4 (κ = 0.11-0.19). LI-RADS produced significantly lower accuracy (78.6% vs. 87.2%) and sensitivity (72.1% vs. 92.8%), higher specificity (97.3% vs. 71.2%) and positive likelihood ratio (+LR: 26.32 vs. 3.23) in diagnosis of HCC. CECT produced relatively low IRA, ICA, and diagnostic ability against MR. CONCLUSION: There were substantial variations in liver observations between LI-RADS and LS. Further study is needed to investigate ICA between CECT and MR.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.003
metaresearch head score (Gemma)0.001
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.253
Threshold uncertainty score0.819

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0030.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.001
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.101
GPT teacher head0.298
Teacher spread0.197 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations40
Published2015
Admission routes1
Has abstractyes

Explore more

Same venueJournal of Magnetic Resonance ImagingSame topicHepatocellular Carcinoma Treatment and PrognosisFrench-language works237,207