Capsule endoscopy for the diagnosis of oesophageal varices in people with chronic liver disease or portal vein thrombosis

2014· review· en· W1619930778 on OpenAlexafffund
Agostino Colli, Juan Cristóbal Gana, Dan Turner, Jason Yap, Thomasin Adams-Webber, Simon C. Ling, Giovanni Casazza

Bibliographic record

VenueCochrane Database of Systematic Reviews · 2014
Typereview
Languageen
FieldMedicine
TopicLiver Disease and Transplantation
Canadian institutionsHospital for Sick ChildrenStollery Children's HospitalUniversity of Alberta
FundersCanadian Institutes of Health Research
KeywordsMedicineVaricesPortal vein thrombosisCapsule endoscopyCirrhosisEndoscopyChronic liver diseasePortal hypertensionInternal medicineGastroenterologyEsophageal varicesGold standard (test)General surgeryRadiology

Abstract

fetched live from OpenAlex

BACKGROUND: Current guidelines recommend performance of oesophago-gastro-duodenoscopy at the time of diagnosis of hepatic cirrhosis to screen for oesophageal varices. These guidelines require people to undergo an unpleasant invasive procedure repeatedly with its attendant risks, despite the fact that half of the people do not have identifiable oesophageal varices 10 years after the initial diagnosis of cirrhosis. Video capsule endoscopy is a non-invasive test proposed as an alternative method for the diagnosis of oesophageal varices. OBJECTIVES: To determine the diagnostic accuracy of capsule endoscopy for the diagnosis of oesophageal varices in children or adults with chronic liver disease or portal vein thrombosis, irrespective of the aetiology. To investigate the accuracy of capsule endoscopy as triage or replacement of oesophago-gastro-duodenoscopy. SEARCH METHODS: We searched the Cochrane Hepato-Biliary Group Diagnostic Test Accuracy Studies Register (October 2013), MEDLINE (Ovid SP) (1950 to October 2013), EMBASE (Ovid SP) (1980 to October 2013), ACP Journal Club (Ovid SP) (1991 to October 2013), Database of Abstracts of Reviews of Effects (DARE) (Ovid SP) (third quarter), Health Technology Assessment (HTA) (Ovid SP) (third quarter), NHS Economic Evaluation Database (NHSEED) (Ovid SP) (third quarter), and Science Citation Index Expanded (SCI-EXPANDED) (ISI Web of Knowledge) (1955 to October 2013). We applied no language or document type restrictions. SELECTION CRITERIA: Studies that evaluated the diagnostic accuracy of capsule endoscopy for the diagnosis of oesophageal varices using oesophago-gastro-duodenoscopy as the reference standard in children or adults of any age, with chronic liver disease or portal vein thrombosis. DATA COLLECTION AND ANALYSIS: We followed the available guidelines provided in the Cochrane Handbook for Diagnostic Test of Accuracy Reviews. We calculated the pooled estimates of sensitivity and specificity using the bivariate model due to the absence of a negative correlation in the receiver operating characteristic (ROC) space and of a threshold effect. MAIN RESULTS: The search identified 16 eligible studies, in which only adults with cirrhosis were included. In one study, people with portal thrombosis were also included. We classified most of the studies at high risk of bias for the 'Participants selection' and the 'Flow and timing' domains. One study assessed the accuracy of capsule endoscopy for the diagnosis of large (high-risk) oesophageal varices. In the remaining15 studies that assessed the accuracy of capsule endoscopy for the diagnosis of oesophageal varices of any size in people with cirrhosis, 936 participants were included; the pooled estimate of sensitivity was 84.8% (95% confidence interval (CI) 77.3% to 90.2%) and of specificity 84.3% (95% CI 73.1% to 91.4%). Eight of these studies included people with suspected varices or people with already diagnosed or even treated varices, or both, introducing a selection bias. Seven studies including only people with suspected but unknown varices were at low risk of bias; the pooled estimate of sensitivity was 79.7% (95% CI 73.1% to 85.0%) and of specificity 86.1% (95% CI 64.5% to 95.5%). Six studies assessed the diagnostic accuracy of capsule endoscopy for the diagnosis of large oesophageal varices, associated with a higher risk of bleeding; the pooled sensitivity was 73.7% (95% CI 52.4% to 87.7%) and of specificity 90.5% (95% CI 84.1% to 94.4%). Two studies also evaluated the presence of red marks, which are another marker of high risk of bleeding; the estimates of sensitivity and specificity varied widely. Two studies obtained similar results with the use of a modified device as index test (string capsule). Due to the absence of data, we could not perform all planned subgroup analyses. Interobserver agreement in the interpretation of capsule endoscopy results and any adverse event attributable to capsule endoscopy were poorly assessed and reported. Only four studies evaluated the interobserver agreement in the interpretation of capsule endoscopy results: the concordance was moderate. The participants' preferences for capsule endoscopy or oesophago-gastro-duodenoscopy were reported differently but seemed in favour of capsule endoscopy in nine of 10 studies. In 10 studies, participants reported some minor discomfort on swallowing the capsule. Only one study identified other significant adverse events, including impaction of the capsule due to previously unidentified oesophageal strictures in two participants. No adverse events were reported as a consequence of the reference standard. AUTHORS' CONCLUSIONS: We cannot support the use of capsule endoscopy as a triage test in adults with cirrhosis, administered before oesophago-gastro-duodenoscopy, despite the low incidence of adverse events and participant reports of being better tolerated. Thus, we cannot conclude that oesophago-gastro-duodenoscopy can be replaced by capsule endoscopy for the detection of oesophageal varices in adults with cirrhosis. We found no data assessing capsule endoscopy in children and in people with portal thrombosis.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMeta-epidemiology (narrow)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Systematic review · Consensus signal: Systematic review
GenreCandidate signal: Review · Consensus signal: Review
Teacher disagreement score0.055
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0020.000
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0060.001
Bibliometrics0.0000.001
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.090
GPT teacher head0.377
Teacher spread0.287 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designSystematic review
Domainnot available
GenreReview

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations47
Published2014
Admission routes2
Has abstractyes

Explore more

Same venueCochrane Database of Systematic ReviewsSame topicLiver Disease and TransplantationFrench-language works237,207