Control of DC bus voltage in single-stage AC-to-DC converter
Bibliographic record
Abstract
This paper presents a control scheme that provides simultaneous control of the output voltage and DC bus voltage of a fixed frequency, single-stage AC-to-DC converter with high frequency transformer isolation. This bus control scheme facilitates utilization of switches with lower voltage ratings in the bridge converter. The control scheme has been explained with analysis. Based on this analysis design example of a 20 kHz, 500 W, 200 V AC-to-DC single-stage bridge converter is presented with explanations on the design constraints. Theoretical results are also predicted based on the analysis. Detailed results obtained from PSPICE simulation are given to verify the advantages claimed for this controlled bus single-stage converter. As a bonus to the bus voltage control, the bottom right switch undergoes zero-voltage switching at reasonably wide load range because of the overlap of the gating signals of two bottom switches in the bridge.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame machine prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.
Distilled classifier scores by category (both heads)
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.000 | 0.000 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.000 | 0.000 |
| Bibliometrics | 0.000 | 0.000 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.001 | 0.000 |
| Open science | 0.001 | 0.000 |
| Research integrity | 0.000 | 0.000 |
| Insufficient payload (model declined to judge) | 0.003 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".