MétaCan
Menu
Back to cohort

A comparison between the GlideScope <sup>®</sup> Video Laryngoscope and direct laryngoscope in paediatric patients with difficult airways – a pilot study

2010· article· en· W1656300872 on OpenAlex

Why this work is in the frame

A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.

affAt least one author lists a Canadian institution in the pinned OpenAlex snapshot.
fundA Canadian funder is recorded on the work.

Bibliographic record

VenueAnaesthesia · 2010
Typearticle
Languageen
FieldMedicine
TopicAirway Management and Intubation Techniques
Canadian institutionsSickKids FoundationHospital for Sick ChildrenUniversity of Toronto
FundersHospital for Sick Children
KeywordsLaryngoscopyVideo laryngoscopeMedicineIntubationAnesthesiaAirwayLaryngoscopesTracheal intubationBlinded studyAirway management

Abstract

fetched live from OpenAlex

The GlideScope Video Laryngoscope may improve the view seen at laryngoscopy in adults who have a difficult airway. Manikin studies and case reports suggest it may also be useful in children, although prospective studies are limited in number. We hypothesised that the paediatric GlideScope will result in an improved view seen at laryngoscopy in children with a known difficult airway, compared to direct laryngoscopy. Eighteen children with a history of difficult or failed intubation were prospectively recruited. After inhalational induction, each patient had laryngoscopy performed using a standard blade followed by GlideScope videolaryngoscopy. The GlideScope yielded a significantly improved laryngoscopic view, both with (p = 0.003) and without (p = 0.004) laryngeal pressure. The mean (SD) time taken to achieve the optimal view was 20 (8)s using conventional laryngoscopy and 26 (22)s using the GlideScope (p = 0.5). The GlideScope significantly improves the laryngoscopic view obtained in children with a difficult airway.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.028
Threshold uncertainty score0.809

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.001
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.015
GPT teacher head0.263
Teacher spread0.249 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it