MétaCan
Menu
Back to cohort
Record W1733446669 · doi:10.1115/imece2014-38875

Method for Characterization of Passive Mechanical Filtration of Particles in Digital Microfluidic Devices

2014· article· en· W1733446669 on OpenAlexafffund
Peter D. Dunning, Pierre E. Sullivan, Michael J. Schertzer

Bibliographic record

Venuenot available
Typearticle
Languageen
FieldEngineering
TopicElectrowetting and Microfluidic Technologies
Canadian institutionsUniversity of Toronto
FundersUniversity of Toronto
KeywordsMicrofluidicsFluidicsDigital microfluidicsMiniaturizationLab-on-a-chipComputer scienceFiltration (mathematics)Materials scienceNanotechnologyFabricationComputer hardwareEngineeringOptoelectronicsElectrowettingElectrical engineering

Abstract

fetched live from OpenAlex

The ability to remove unbound biological material from a reaction site has applications in many biological protocols, such as those used to detect pathogens and biomarkers. One specific application where washing is critical is the Enzyme-Linked ImmunoSorbent Assay (ELISA). This protocol requires multiple washing steps to remove multiple reagents from a reaction site. Previous work has suggested that a passive mechanical comb filter can be used to wash particles in digital microfluidic devices. A method for the characterization of passive mechanical filtration of particles in Digital MicroFluidic (DMF) devices is presented in this work. In recent years there has been increased development of Lab-On-A-Chip (LOAC) devices for the automation and miniaturization of biological protocols. One platform for further research is in digital microfluidics. A digital microfluidic device can control the movement of pico-to nanoliter droplets of fluid using electrical signals without the use of pumps, valves, and channels. As such, fluidic pathways are not hardwired and the path of each droplet can be easily reconfigured. This is advantageous in biological protocols requiring the use of multiple reagents. Fabrication of these devices is relatively straight forward, since fluid manipulation is possible without the use of complex components. This work presents a method to characterize the performance of a digital microfluidic device using passive mechanical supernatant dilution via image analysis using a low cost vision system. The primary metric for performance of the device is particle retention after multiple passes through the filter. Repeatability of the process will be examined by characterizing performance of multiple devices using the same filter geometry. Qualitative data on repeatability and effectiveness of the dilution technique will also be attained by observing the ease with which the droplet disengages from the filter and by measuring the quantity of fluid trapped on the filter after each filtration step.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.411
Threshold uncertainty score0.225

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.007
GPT teacher head0.225
Teacher spread0.218 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2014
Admission routes2
Has abstractyes

Explore more

Same topicElectrowetting and Microfluidic TechnologiesFrench-language works237,207