MétaCan
Menu
← Back to cohort
Record W1769493060

An outbreak of hepatitis B associated with reusable subdermal electroencephalogram electrodes.

2000· article· en· W1769493060 on OpenAlexvenueno aff
Ian L. Johnson

Bibliographic record

VenueCanadian Medical Association Journal · 2000
Typearticle
Languageen
FieldImmunology and Microbiology
TopicMedical Device Sterilization and Disinfection
Canadian institutionsnot available
Fundersnot available
KeywordsOutbreakComputer scienceElectroencephalographyHepatitisMedicineVirologyPsychiatry
DOInot available

Abstract

fetched live from OpenAlex

BACKGROUND: In early 1996 an outbreak of hepatitis B was detected among patients who attended an electroencephalogram (EEG) clinic in Toronto operated by a neurologist. In this article we report the results of an investigation conducted to determine the extent and source of the outbreak. METHODS: Notifications were sent to 18 567 patients who had attended any of 6 EEG clinics operated by the neurologist between 1990 and 1996 asking them to see their physician to be tested for hepatitis B virus (HBV) infection; 2957 envelopes were returned. Of the remaining 15 610 patients, results of laboratory tests were available for 10 244 (65.6%). A detailed follow-up of patients with newly acquired hepatitis B and those with chronic infection (carriers) was conducted. Viral DNA sequencing was used to compare strains of available HBV isolates. RESULTS: A total of 75 patients were identified in whom hepatitis B developed between 1991 and 1996; all of them had had at least one EEG performed in which reusable subdermal electrodes had been used. No cases were detected among patients who participated only in sleep studies, for which disk electrodes had been used. The peak rate of HBV infection (18.2 cases per 1000 person-EEGs) occurred in 1995. One technician performed all of the EEGs at the clinics and was found to be positive for hepatitis B e antigen. DNA sequencing confirmed that the virus isolated from the technician was identical to the virus isolated in 4 cases of hepatitis B tested. Infection control procedures were found to be inadequate. INTERPRETATION: The hepatitis B outbreak was a result of a common source of infection, the technologist, and inadequate infection control practices. Reusable subdermal EEG electrodes were the likely vehicles of transmission. Health care workers should follow recommended infection control practices and be vaccinated against hepatitis B.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.004
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Case report · Consensus signal: Case report
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.083
Threshold uncertainty score0.165

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.004
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0000.001
Bibliometrics0.0010.001
Science and technology studies0.0030.002
Scholarly communication0.0010.001
Open science0.0010.001
Research integrity0.0060.005
Insufficient payload (model declined to judge)0.0020.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.003
GPT teacher head0.205
Teacher spread0.202 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designCase report
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations31
Published2000
Admission routes1
Has abstractno

Explore more

Same venueCanadian Medical Association Journal→Same topicMedical Device Sterilization and Disinfection→French-language works237,207→