MétaCan
Menu
Back to cohort
Record W1775883216 · doi:10.2136/sssaj2014.10.0413

An Efficient Calibration Technique for Heat Dissipation Matric Water Potential Sensors

2015· article· en· W1775883216 on OpenAlexafffund
Xicai Pan, Andrew Ireson, Warren Helgason, Kwok Pan Chun

Bibliographic record

VenueSoil Science Society of America Journal · 2015
Typearticle
Languageen
FieldEngineering
TopicSoil and Unsaturated Flow
Canadian institutionsUniversity of SaskatchewanGlobal Institute for Water Security
FundersGlobal Institute for Water Security, University of SaskatchewanUniversity of Saskatchewan
KeywordsCalibrationWater potentialRange (aeronautics)DissipationCalibration curveMeasure (data warehouse)Measurement uncertaintyEnvironmental scienceMathematicsSoil scienceRemote sensingStatisticsSoil waterThermodynamicsComputer sciencePhysicsMaterials scienceGeologyData mining

Abstract

fetched live from OpenAlex

Heat dissipation sensors are used to measure matric potential in soils. A van Genuchten equation can be used to fit the relationship between measured heat dissipation and matric potential. Calibration is required for each probe because of intrinsic variability in the properties of the porous material. However, calibration is time-consuming (months), requiring numerous measurements taken by a pressure plate apparatus over their operational range. Here the feasibility of minimizing the number of measurement points required to reliably characterize the calibration curve is explored. A two parameter (m = 1−1/n) and a three parameter (m is a free parameter) van Genuchten type model is used for the calibration. We explore how reducing the number of calibration measurement points impacts the resulting calibration curve, that is, what is the information content that each measurement provides, and how significantly is the calibration performance degraded by removing measurement points. We also consider how measurement errors during the calibration process, which are understood to be non-uniform over the range of matric potential values, result in uncertainty in the calibration curve, and explore how this uncertainty can be minimized. Different measurement locations (i.e., matric potential values) are found to contain different information content. A two-parameter-model calibration using four calibration points is recommended; and the specific location of these four points is essential to maximize the accuracy and the efficiency of the calibration. As a rule of thumb, the four points should be uniformly distributed on a log-scale over the pressure range from 20 to 1000 kPa.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.004
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Methods · Consensus signal: Methods
Teacher disagreement score0.002
Threshold uncertainty score0.007

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.004
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0010.001
Science and technology studies0.0000.000
Scholarly communication0.0010.001
Open science0.0010.001
Research integrity0.0010.002
Insufficient payload (model declined to judge)0.0020.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.009
GPT teacher head0.239
Teacher spread0.230 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreMethods

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2015
Admission routes2
Has abstractyes

Explore more

Same venueSoil Science Society of America JournalSame topicSoil and Unsaturated FlowFrench-language works237,207