MétaCan
Menu
Back to cohort
Record W1777937531 · doi:10.1177/039139880803100205

Fluid and Volume Monitoring

2008· review· en· W1777937531 on OpenAlexaff
Michael R. Pinsky, P. Brophy, Juan I Padilla, Neesh Pannu

Bibliographic record

VenueThe International Journal of Artificial Organs · 2008
Typereview
Languageen
FieldMedicine
TopicHemodynamic Monitoring and Therapy
Canadian institutionsUniversity of Alberta
Fundersnot available
KeywordsHypovolemiaIntravascular volume statusMedicineResuscitationIntensive care medicineAcute kidney injuryPulse pressureStroke volumeHypervolemiaBlood volumeShock (circulatory)Blood pressureCardiologyHemodynamicsInternal medicineEmergency medicineHeart rate

Abstract

fetched live from OpenAlex

BACKGROUND: Fluid resuscitation is not only used to prevent acute kidney injury (AKI) but fluid management is also a cornerstone of treatment for patients with established AKI and renal failure. Ultrafiltration removes volume initially from the intravascular compartment inducing a relative degree of hypovolemia. Normal reflex mechanisms attempt to sustain blood pressure constant despite marked changes in blood volume and cardiac output. Thus, compensated shock with a normal blood pressure is a major cause of AKI or exacerbations of AKI during ultrafiltration. METHODS: We undertook a systematic review of the literature using MEDLINE, Google Scholar and PubMed searches. We determined a list of key questions and convened a 2-day consensus conference to develop summary statements via a series of alternating breakout and plenary sessions. In these sessions, we identified supporting evidence and generated clinical practice recommendations and/or directions for future research. RESULTS: We defined three aspects of fluid monitoring: i) normal and pathophysiological cardiovascular mechanisms; ii) measures of volume responsiveness and impending cardiovascular collapse during volume removal, and; iii) measured indices of each using non-invasive and minimally invasive continuous and intermittent monitoring techniques. The evidence documents that AKI can occur in the setting of normotensive hypovolemia and that under-resuscitation represents a major cause of both AKI and mortality ion critically ill patients. Traditional measures of intravascular volume and ventricular filling do not predict volume responsiveness whereas dynamic functional hemodynamic markers, such as pulse pressure or stroke volume variation during positive pressure breathing or mean flow changes with passive leg raising are highly predictive of volume responsiveness. Numerous commercially-available devices exist that can acquire these signals. CONCLUSIONS: Prospective clinical trials using functional hemodynamic markers in the diagnosis and management of AKI and volume status during ultrafiltration need to be performed. More traditional measure of preload be abandoned as marked of volume responsiveness though still useful to assess overall volume status.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Other design · Consensus signal: none
GenreCandidate signal: Review · Consensus signal: Review
Teacher disagreement score0.998
Threshold uncertainty score0.454

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.056
GPT teacher head0.360
Teacher spread0.304 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designOther design
Domainnot available
GenreReview

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations49
Published2008
Admission routes1
Has abstractyes

Explore more

Same venueThe International Journal of Artificial OrgansSame topicHemodynamic Monitoring and TherapyFrench-language works237,207