MétaCan
Menu
Back to cohort
Record W18120083

Droplet actuation on various electrode shapes in electrowetting-based microfluidics

2009· dissertation· en· W18120083 on OpenAlexfundno aff
Negar Rajabi

Bibliographic record

Venue˜El œdía médico · 2009
Typedissertation
Languageen
FieldEngineering
TopicElectrowetting and Microfluidic Technologies
Canadian institutionsnot available
FundersMinistère du Développement Économique, de l’Innovation et de l’Exportation
KeywordsElectrowettingDigital microfluidicsElectrodeMicrofluidicsMaterials scienceMechanicsLaplace's equationFluidicsMicrosystemNanotechnologyEngineeringPhysicsElectrical engineeringBoundary value problem
DOInot available

Abstract

fetched live from OpenAlex

Electrowetting has been widely used in digital microfluidics as a reliable actuation method due to its considerable advantages such as the absence of heat generation, rapid switching response, flexibility, and low power consumption. Research on the improvement of this method has turned into one of the attractive fields in the design of fluid handling micro devices. This work presents a combined numerical and experimental study to investigate the effect of electrode shape in electrowetting-based microsystems. A new crescent-shaped electrode is proposed which provides a uniform actuation force at the contact line as well as overlap between the adjacent electrodes. The onset of actuation and droplet mobility on electrode arrays have been investigated. The numerical method is based on the Volume of Fluid technique to track the 3-D interface along with the Laplace equation solver to calculate the electric field in the domain. Furthermore, the dynamic behaviour of tri-phase contact line is modeled using the molecular-kinetic theory. Validation experiments were carried out to characterize the droplet actuation on various electrode shapes. The superior performance of the new electrode shape is demonstrated by comparing the droplet velocity and deformation, as well as contact angle distribution with those of a simple flat electrode. Using crescent electrode, the droplet actuation occurs with less deformation and higher velocities. The velocities obtained by using the crescent electrode are up to 4 times at the onset of the actuation and 2 times at the steady state motion of those on the flat electrode. The novel crescent shape can even actuate the droplets which are not placed on the electrode

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMeta-epidemiology (narrow), Research integrity
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.068
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0010.001
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0010.000
Research integrity0.0010.002
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.005
GPT teacher head0.225
Teacher spread0.220 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations1
Published2009
Admission routes1
Has abstractyes

Explore more

Same venue˜El œdía médicoSame topicElectrowetting and Microfluidic TechnologiesFrench-language works237,207