MétaCan
Menu
Back to cohort
Record W1819339164 · doi:10.1002/mrm.24830

Optimizing contrast agent concentration and spoiled gradient echo pulse sequence parameters for catheter visualization in MR‐guided interventional procedures: An analytic solution

2013· article· en· W1819339164 on OpenAlexaff
Marshall S. Sussman, Uri Lindner, Masoom A. Haider, Walter Kucharczyk, Eugen Hlasny, John Trachtenberg

Bibliographic record

VenueMagnetic Resonance in Medicine · 2013
Typearticle
Languageen
FieldMedicine
TopicAdvanced MRI Techniques and Applications
Canadian institutionsSunnybrook Health Science CentreUniversity of TorontoHealth Sciences CentreUniversity Health Network
Fundersnot available
KeywordsContrast (vision)VisualizationFlip anglePulse sequenceImaging phantomComputer scienceGradient echoGadoliniumBiomedical engineeringNuclear magnetic resonanceMaterials scienceMagnetic resonance imagingNuclear medicinePhysicsRadiologyMedicineArtificial intelligence

Abstract

fetched live from OpenAlex

PURPOSE: A critical requirement of MR-guided interventions is the visualization of an instrument (e.g., catheter, needle) during the procedure. One approach is to fill the instrument with a contrast agent. Previously, the optimization of contrast agent visualization was performed only empirically. In the present study, an analytic optimization of contrast agent SNR efficiency was performed for a spoiled gradient echo pulse sequence. METHODS: Optimal flip angle, repetition time, echo time, and contrast agent concentration were derived analytically. The solution is valid for any contrast agent, provided the relationship between T1 , T2 , and doping concentration is known. RESULTS: Phantom experiments validated the analytic optimization for Gd- and MnCl2 -based contrast agents. Results showed excellent agreement between experimentally predicted and theoretically observed magnetization behavior. In vivo experiments demonstrated optimized contrast agent visualization in brain, heart, and prostate applications. The results demonstrated the large SNR that can be achieved with analytic optimization. As a practical guideline, an 11% dilution of 500 mMol/L Gd-DTPA solution, repetition time ≈ 4 ms, echo time ≈ 1 ms, and θ ≈ 65° was found to provide a large SNR. CONCLUSION: This study derived and validated a method for analytically optimizing contrast agent SNR efficiency. This information may be useful for visualizing instruments during MR-guided interventions.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.005
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: none
GenreCandidate signal: Methods · Consensus signal: Methods
Teacher disagreement score0.001
Threshold uncertainty score0.009

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.005
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0010.000
Science and technology studies0.0000.001
Scholarly communication0.0010.001
Open science0.0010.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.048
GPT teacher head0.360
Teacher spread0.313 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designSimulation or modeling
Domainnot available
GenreMethods

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations7
Published2013
Admission routes1
Has abstractyes

Explore more

Same venueMagnetic Resonance in MedicineSame topicAdvanced MRI Techniques and ApplicationsFrench-language works237,207