MétaCan
Menu
Back to cohort
Record W1825848354 · doi:10.1177/112972980901000308

Measurement of the International Normalized Ratio (INR) in Hemodialysis Patients with Heparin-Locked Central venous Catheters: Evaluation of a Novel Blood Sampling Method

2009· article· en· W1825848354 on OpenAlexaff
Jean‐Philippe Rioux, Bruno De Bortoli, Serge Quérin, Clément Déziel, Stéphan Troyanov, François Madore

Bibliographic record

VenueThe Journal of Vascular Access · 2009
Typearticle
Languageen
FieldHealth Professions
TopicCentral Venous Catheters and Hemodialysis
Canadian institutionsHôpital du Sacré-Cœur de Montréal
Fundersnot available
KeywordsVenipunctureMedicineHemodialysisHeparinDialysisCentral venous catheterWarfarinBlood samplingCatheterAnticoagulantAnesthesiaSurgeryUrologyCardiologyInternal medicine

Abstract

fetched live from OpenAlex

BACKGROUND: Accurate measurement of the international normalized ratio (INR) may be difficult in hemodialysis (HD) patients with heparin-locked central catheters. Blood contamination with locking solutions may interfere with INR measurement when samples are collected directly from the catheter. METHODS: The aim of our study was to evaluate a novel sampling method for the measurement of INR in HD patients with heparin-locked central catheters. This novel method consists of measuring the INR directly from the dialysis circuit (arterial bloodline sample port) after 1 hr of treatment regardless of heparin administration during dialysis. We compared this method to the gold standard (peripheral venipuncture prior to dialysis) using the paired t-test. We included 30 patients (23 with warfarin therapy and 7 without). RESULTS: INRs obtained using the novel sampling method were only minimally overestimated compared to venipuncture values (mean INR overestimation: 0.2 +/- 0.2). This overestimation was not clinically significant and did not lead to changes in warfarin prescription for any of the patients. Correlation tests confirmed the influence of heparin administration on INR overestimation (R=0.4; p=0.05). This influence was present mostly among patients receiving more than 100 Units/kg of heparin during their treatment. CONCLUSION: This novel sampling technique provides a convenient and simple method of monitoring INR among HD patients.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.003
metaresearch head score (Gemma)0.008
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.003
Threshold uncertainty score0.013

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0030.008
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0010.000
Science and technology studies0.0000.000
Scholarly communication0.0010.000
Open science0.0010.000
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.090
GPT teacher head0.385
Teacher spread0.295 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations14
Published2009
Admission routes1
Has abstractyes

Explore more

Same venueThe Journal of Vascular AccessSame topicCentral Venous Catheters and HemodialysisFrench-language works237,207