MétaCan
Menu
Back to cohort
Record W1843764126 · doi:10.1117/1.jbo.20.12.121310

Double-integrating-sphere system at the National Institute of Standards and Technology in support of measurement standards for the determination of optical properties of tissue-mimicking phantoms

2015· article· en· W1843764126 on OpenAlexaff
Paul Lemaillet, Jean‐Pierre Bouchard, Jeeseong Hwang, David W. Allen

Bibliographic record

VenueJournal of Biomedical Optics · 2015
Typearticle
Languageen
FieldMedicine
TopicOptical Imaging and Spectroscopy Techniques
Canadian institutionsInstitut National d'Optique
FundersInformation Technology LaboratoryNational Institute of Standards and Technology
KeywordsIntegrating sphereRepeatabilityAttenuation coefficientOpticsMeasure (data warehouse)Scattering coefficientScatteringComputer scienceMaterials scienceBiological tissueAbsorption (acoustics)Biomedical engineeringPolarization (electrochemistry)Light scatteringPhysicsMathematicsStatisticsData miningChemistry

Abstract

fetched live from OpenAlex

There is a need for a common reference point that will allow for the comparison of the optical properties of tissue-mimicking phantoms. After a brief review of the methods that have been used to measure the phantoms for a contextual backdrop to our approach, this paper reports on the establishment of a standardized double-integrating-sphere platform to measure absorption and reduced scattering coefficients of tissue-mimicking biomedical phantoms. The platform implements a user-friendly graphical user interface in which variations of experimental configurations and model-based analysis are implemented to compute the coefficients based on a modified inverse adding-doubling algorithm allowing a complete uncertainty evaluation. Repeatability and validation of the measurement results of solid phantoms are demonstrated for three samples of different thicknesses, d = 5.08 mm, 7.09 mm, and 9.92 mm, with an absolute error estimate of 4.0% to 5.0% for the absorption coefficient and 11% to 12% for the reduced scattering coefficient (k = 2). The results are in accordance with those provided by the manufacturer. Measurements with different polarization angles of the incident light are also presented, and the resulting optical properties were determined to be equivalent within the estimated uncertainties.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.043
metaresearch head score (Gemma)0.036
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.043
Threshold uncertainty score0.228

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0430.036
Meta-epidemiology (narrow)0.0020.001
Meta-epidemiology (broad)0.0030.001
Bibliometrics0.0070.006
Science and technology studies0.0030.002
Scholarly communication0.0040.003
Open science0.0060.004
Research integrity0.0030.005
Insufficient payload (model declined to judge)0.0070.008

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.054
GPT teacher head0.365
Teacher spread0.310 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations34
Published2015
Admission routes1
Has abstractyes

Explore more

Same venueJournal of Biomedical OpticsSame topicOptical Imaging and Spectroscopy TechniquesFrench-language works237,207