PWM inverter active filters for industrial drive systems under unbalanced AC supply conditions
Bibliographic record
Abstract
The performance curves for a wide range of PWM inverter harmonic correction topologies are examined that draw sinusoidal supply currents and that can be attached to the input stage of standard industrial drive systems. The PWM inverter cells examined can operate with current ratings as low as 0.3 pu. When the PWM inverter harmonic correction cell is separated from the drive rectifier, its RMS currents increases significantly as the drive filter inductance is lowered and the more unbalanced the AC supply becomes. This is due to the PWM inverter cell compensating for large harmonics and harmonic imbalances between phases. PWM inverter harmonic correction topologies that are integrated with the drive input stage can lower these adverse effects, and can be divided into two classes: (a) zero power flow, and (b) positive power flow.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame distilled prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.
Codex and Gemma teacher scores by category
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.000 | 0.000 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.000 | 0.000 |
| Bibliometrics | 0.000 | 0.000 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.000 | 0.000 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.000 | 0.000 |
| Insufficient payload (model declined to judge) | 0.001 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one teacher head, not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".