MétaCan
Menu
Back to cohort
Record W1845424267 · doi:10.1111/evj.12486_62

<scp>P</scp> ost Exercise Cardiac Troponin <scp>I</scp> Release and Clearance in Normal Standardbred Racehorses

2015· article· en· W1845424267 on OpenAlexaffabout
Tanya Rossi, D.L. Pearl, W. Glen Pyle, M.G. Maxie, Peter A. Kavsak, Peter W. Physick‐Sheard

Bibliographic record

VenueEquine Veterinary Journal · 2015
Typearticle
Languageen
FieldVeterinary
TopicVeterinary Equine Medical Research
Canadian institutionsMcMaster UniversityUniversity of Guelph
FundersUniversiteit UtrechtRural Industries Research and Development CorporationUniversity of MelbourneNew Zealand Equine Research FoundationMassey UniversityHelsingin Yliopisto
KeywordsTroponin IHorseMedicineBlood samplingInternal medicineCardiologyTroponinBiologyMyocardial infarction

Abstract

fetched live from OpenAlex

Reasons for performing study There are currently no studies detailing cardiac troponin I (cTnI) release and clearance in normal horses post exercise using an analytically validated assay. These data are essential for selecting appropriate sampling times in equine athletes with suspected myocardial damage. Objective To plot the magnitude and time course of cTnI release and clearance, using a validated cTnI assay, after maximal effort. Study design Descriptive longitudinal study. Methods Five clinically normal Standardbred racehorses in full race training were included in the study. Physical examinations were performed on subjects and blood samples were taken via jugular venipuncture pre‐exercise. Horses were exercised in harness at race intensity in groups on a training track. A second blood sample was taken immediately post exercise and an intravenous catheter was then placed in a jugular vein. Hourly blood samples were taken for 24 h. All samples were collected in red top serum Vacutainer® tubes and allowed to clot for 30 min before being centrifuged and serum harvested. Serum samples were stored at −80° C until analysis. All samples were analysed using the Abbott ARCHITECT STAT High Sensitivity cTnI® assay. Results Mean resting cTnI level was 1.33 ± 0.6 ng/l (range, 0.82–2.33 ng/l). All horses exhibited an increase in cTnI level after exercise with peak elevation occurring 2–6 h post exercise (mean, 4.6 ± 1.7 h). Mean peak increase in cTnI level was 11.96 ± 9.41 ng/l (range, 1.72–23.76 ng/l). All horses returned to baseline levels within 24 h. Conclusions All horses experienced an increase in cTnI post exercise, with the peak occurring 2–6 h post exercise. Further studies are needed to determine the significance of these increases. Ethical animal research: The study protocol was approved by the University's Animal Care Committee. Explicit informed consent was obtained in writing for all client‐owned animals. Source of funding: Equine Guelph. Competing interests: Dr Kavsak has received grants/honoraria/consultant/advisor fees from Abbott Laboratories, Abbott Point of Care, Beckman Coulter, Ortho Clinical Diagnostics, Randox Laboratories, Roche Diagnostics, and the Canadian Agency for Drugs and Technologies in Health. He is listed as an inventor on patents filed by McMaster University related to laboratory testing in acute cardiac care. No funding was received from the manufacturer of the assay evaluated in this study.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.004
metaresearch head score (Gemma)0.007
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMeta-epidemiology (narrow), Research integrity
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Not applicable · Consensus signal: Not applicable
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.353
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0040.007
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0010.001
Science and technology studies0.0000.001
Scholarly communication0.0010.002
Open science0.0010.001
Research integrity0.0000.003
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.078
GPT teacher head0.354
Teacher spread0.276 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designNot applicable
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations10
Published2015
Admission routes2
Has abstractyes

Explore more

Same venueEquine Veterinary JournalSame topicVeterinary Equine Medical ResearchFrench-language works237,207