MétaCan
Menu
Back to cohort
Record W1854847768 · doi:10.25011/cim.v38i5.25686

Does stent strut design impact clinical outcomes: comparative safety and efficacy of Endeavor Resolute versus Resolute Integrity zotarolimus-eluting stents

2015· article· en· W1854847768 on OpenAlexaffvenue
Pietro Di Santo, Trevor Simard, F. Daniel Ramirez, Ali Pourdjabbar, David T. Harnett, Kuljit Singh, Robert B. Moreland, Aun‐Yeong Chong, Alexander Dick, Marino Labinaz, Michael Froeschl, M.R. Le May, Derek So, Benjamin Hibbert, Christopher Glover

Bibliographic record

VenueClinical and investigative medicine · 2015
Typearticle
Languageen
FieldMedicine
TopicCoronary Interventions and Diagnostics
Canadian institutionsUniversity of Ottawa
Fundersnot available
KeywordsMedicineStentZotarolimusInternal medicineDrug-eluting stent

Abstract

fetched live from OpenAlex

UNLABELLED: Percutaneous coronary intervention is the most commonly performed method of revascularizing obstructive coronary artery disease. The impact of stent strut design on clinical outcomes remains unclear. The Endeavour Resolute (ER-ZES) and the Resolute Integrity (RI-ZES) zotarolimus-eluting stents utilize identical polymers and anti-proliferative agents, differing only in their respective strut design. This study assessed the comparative safety and efficacy of these two stents in unrestricted contemporary real-world practice. METHODS: A total of 542 patients were identified, corresponding to 340 ER-ZES and 480 RI-ZES. The primary endpoint was major adverse cardiac events (MACE) defined by a composite of death, nonfatal myocardial infarction and stroke. Secondary endpoints included post-procedural length of stay, in-stent restenosis, target lesion revascularization, target vessel revascularization, coronary artery bypass grafting and stent thrombosis. RESULTS: MACE occurred in 3.2% of the ER-ZES cohort and 5.0% of the RI-ZES cohort (p= 0.43). Adjusted analysis utilizing propensity score-adjusted odds ratio for MACE, was 1.37 (95% CI 0.46-4.07, p=0.57). The mortality rate (0.9% ER-ZES vs. 1.9% RI-ZES, p=0.59), non-fatal MI (2.3% ER-ZES vs. 3.1% RI-ZES, p=0.75) and stroke (0.0% ER-ZES vs. 0.3% RI-ZES, p=0.85) were not different. Additionally, there was no difference in any of secondary outcomes. CONCLUSIONS: The clinical performance and safety of both ER-ZES and RI-ZES were not statistically different, despite differences in stent strut design.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.004
metaresearch head score (Gemma)0.032
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMetaresearch, Science and technology studies
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.028
Threshold uncertainty score0.994

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0040.032
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0020.000
Bibliometrics0.0000.000
Science and technology studies0.0000.009
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.509
GPT teacher head0.481
Teacher spread0.028 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations9
Published2015
Admission routes2
Has abstractyes

Explore more

Same venueClinical and investigative medicineSame topicCoronary Interventions and DiagnosticsFrench-language works237,207