MétaCan
Menu
Back to cohort
Record W1857231848 · doi:10.1117/1.jbo.20.6.066007

Determination of biodistribution of ultrasmall, near-infrared emitting gold nanoparticles by photoacoustic and fluorescence imaging

2015· article· en· W1857231848 on OpenAlexafffund
Wilson Poon, Andrew Heinmiller, Xuan Zhang, Jay Nadeau

Bibliographic record

VenueJournal of Biomedical Optics · 2015
Typearticle
Languageen
FieldEngineering
TopicPhotoacoustic and Ultrasonic Imaging
Canadian institutionsMcGill UniversityFujiFilm VisualSonics (Canada)University of Toronto
FundersCanadian Institutes of Health ResearchNatural Sciences and Engineering Research Council of CanadaCanada Research ChairsMinistère du Développement Économique, de l’Innovation et de l’ExportationCalifornia HIV/AIDS Research Program
KeywordsBiodistributionFluorescence-lifetime imaging microscopyFluorescenceMaterials scienceNanoparticleMolecular imagingPlasmonPreclinical imagingAbsorbanceAnalytical Chemistry (journal)ChemistryOpticsNanotechnologyOptoelectronicsIn vivoChromatographyPhysics

Abstract

fetched live from OpenAlex

This study compares fluorescence and photoacoustic (PA) imaging of ex vivo tumors and organs from tumor-bearing mice injected intravenously with ultrasmall (<3 nm ) tiopronin-capped Au nanoparticles and compares the data with inductively coupled plasma mass spectrometry (ICP-MS). Good agreement is seen in particle distributions and concentrations at the organ level. The spatial resolution from the imaging techniques allows for localization of the particles within organ structures. Although the particles do not have a plasmon peak, their absorbance in the near-infrared (NIR) is sufficient for PA excitation. PA imaging shows an increase of signal as particle concentrations increase, with changes in spectrum if particles aggregate. Fluorescence imaging using the particles’ native NIR emission shows agreement in general intensity in each organ, though quenching of emission can be seen at very high concentrations. Both of these imaging techniques are noninvasive and labor-saving alternatives to organ digestion and ICP-MS and may provide insight into cellular distribution of particles. The simple construct avoids the use of toxic semiconductor materials or dyes, relying upon the gold itself for both the fluorescence and PA signal. This provides a useful alternative to more complex approaches to multimodal imaging and one that is readily translatable to the clinic.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.741
Threshold uncertainty score0.401

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.008
GPT teacher head0.219
Teacher spread0.211 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations19
Published2015
Admission routes2
Has abstractyes

Explore more

Same venueJournal of Biomedical OpticsSame topicPhotoacoustic and Ultrasonic ImagingFrench-language works237,207