MétaCan
Menu
Back to cohort
Record W1891468778 · doi:10.1002/mrm.24945

The evaluation of steerable ultrasonic catheters for minimally invasive MRI‐guided cardiac ablation

2013· article· en· W1891468778 on OpenAlexaff
Mathew Carias, Kullervo Hynynen

Bibliographic record

VenueMagnetic Resonance in Medicine · 2013
Typearticle
Languageen
FieldEngineering
TopicUltrasound and Hyperthermia Applications
Canadian institutionsUniversity of TorontoSunnybrook Health Science Centre
Fundersnot available
KeywordsUltrasoundImaging phantomCatheterAblationBiomedical engineeringCardiac AblationInterventional magnetic resonance imagingUltrasonic sensorCatheter ablationSpecific absorption rateEx vivoFocused ultrasoundNuclear medicineMedicineMagnetic resonance imagingIn vivoMaterials scienceRadiologyComputer science

Abstract

fetched live from OpenAlex

PURPOSE: The purpose of this study was to develop steerable MR-compatible ultrasound catheters suitable for minimally invasive MRI-guided cardiac ablation therapies. METHODS: MRI-compatible ultrasound steerable catheters were developed and tested for their overall tissue heating performance and safety. Ultrasound transducers were mounted on a monodirectional deflectable catheter tip that was made to be MRI-compatible. Catheter safety was assessed on the potential to form hot spots at the distal end of the catheter throughout fast spin echo and thermometry scans. Heating experiments were performed on phantoms and ex vivo porcine cardiac samples. RESULTS: During catheter safety experiments, a maximum temperature increase of 11.35 ± 0.83°C was evident after a 12-min, 40-s fast spin echo scan with a whole body specific absorption rate (SAR) of 1.9 W/kg and 1.07 ± 0.22°C during thermometry scans (flip angle = 90°; scan time = 12 min, 41 s; whole body SAR = 0.34 W/kg). Temperature elevations induced by the sonication were shown to be on the order of 38.1 ± 5.2°C for phantom experiments and 49.3 ± 9.7°C for ex vivo cardiac samples. CONCLUSION: Steerable ultrasound catheters have the potential to be safely placed in an MR system with little concern of catheter self-heating and driven to heat surrounding structures to cause ablations. In addition, these catheters have the added benefit of a deflectable tip that allows the treatment of multiple targets from within the bore of the MR scanner.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.002
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.001
Threshold uncertainty score0.004

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.002
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.023
GPT teacher head0.265
Teacher spread0.242 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations6
Published2013
Admission routes1
Has abstractyes

Explore more

Same venueMagnetic Resonance in MedicineSame topicUltrasound and Hyperthermia ApplicationsFrench-language works237,207