MétaCan
Menu
Back to cohort
Record W1893290019 · doi:10.1002/lt.24340

Subnormothermic ex vivo liver perfusion is a safe alternative to cold static storage for preserving standard criteria grafts

2015· article· en· W1893290019 on OpenAlexafffund
Vinzent N. Spetzler, Nicolás Goldaracena, Juan Echiverri, J. Moritz Kaths, Kristine S. Louis, Oyedele Adeyi, Paul S. F. Yip, David Grant, Nazia Selzner, Markus Selzner

Bibliographic record

VenueLiver Transplantation · 2015
Typearticle
Languageen
FieldMedicine
TopicOrgan Transplantation Techniques and Outcomes
Canadian institutionsUniversity of TorontoToronto General Hospital
FundersCanadian Donation and Transplantation Research Program
KeywordsMedicineEx vivoLiver transplantationLiver perfusionPerfusionCold storageSurgeryIn vivoTransplantationRadiology

Abstract

fetched live from OpenAlex

We developed a novel technique of subnormothermic ex vivo liver perfusion (SNEVLP) for the storage of liver grafts before transplantation. To test the safety of SNEVLP for the nonextended criteria grafts (standard grafts), we compared it to a control group with minimal cold static storage (CS) time. Heart-beating pig liver retrieval was performed. Grafts were either stored in cold unmodified University of Wisconsin solution (CS-1), in cold University of Wisconsin solution with ex vivo perfusion additives (CS-2), or preserved with a sequence of 3 hours CS and 3 hours SNEVLP (33°C), followed by orthotopic liver transplantation. Liver function tests and histology were investigated. Aspartate aminotransferase (AST) levels during SNEVLP remained stable (54.3 ± 12.6 U/L at 1 hour to 47.0 ± 31.9 U/L at 3 hours). Posttransplantation, SNEVLP versus CS-1 livers had decreased AST levels (peak at day 1, 1081.9 ± 788.5 versus 1546.7 ± 509.3 U/L; P = 0.14; at day 2, 316.7 ± 188.1 versus 948.2 ± 740.9 U/L; P = 0.04) and alkaline phosphatase levels (peak at day 1, 150.4 ± 19.3 versus 203.7 ± 33.6 U/L; P = 0.003). Bilirubin levels were constantly within the physiological range in the SNEVLP group, whereas the CS-1 group presented a large standard deviation, including pathologically increased values. Hyaluronic acid as a marker of endothelial cell (EC) function was markedly improved by SNEVLP during the early posttransplant phase (5 hours posttransplant, 1172.75 ± 598.5 versus 5540.5 ± 2755.4 ng/mL). Peak international normalized ratio was similar between SNEVLP and CS-1 groups after transplantation. Immunohistochemistry for cleaved caspase 3 demonstrated more apoptotic sinusoidal cells in the CS-1 group when compared to SNEVLP grafts 2 hours after reperfusion (19.4 ± 19.5 versus 133.2 ± 48.8 cells/high-power field; P = 0.002). Adding normothermic CS-2 had no impact on liver injury or function after transplantation when compared to CS-1. In conclusion, SNEVLP is safe to use for standard donor grafts and is associated with improved EC and bile duct injury even in grafts with minimal CS time.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.566
Threshold uncertainty score0.924

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.037
GPT teacher head0.317
Teacher spread0.280 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations36
Published2015
Admission routes2
Has abstractyes

Explore more

Same venueLiver TransplantationSame topicOrgan Transplantation Techniques and OutcomesFrench-language works237,207