MétaCan
Menu
Back to cohort
Record W1902888488 · doi:10.1002/mrm.24621

Compressed sensing reconstruction improves sensitivity of variable density spiral fMRI

2013· article· en· W1902888488 on OpenAlexafffund
Daniel J. Holland, C. Liu, Xianlin Song, Erin L. Mazerolle, M. Tynan R. Stevens, Andrew J. Sederman, Lynn F. Gladden, Ryan C.N. D’Arcy, Chris V. Bowen, Steven Beyea

Bibliographic record

VenueMagnetic Resonance in Medicine · 2013
Typearticle
Languageen
FieldMedicine
TopicAdvanced MRI Techniques and Applications
Canadian institutionsDalhousie UniversityNational Research Council CanadaNational Research Council Institute for Biodiagnostics
FundersEngineering and Physical Sciences Research CouncilNatural Sciences and Engineering Research Council of CanadaMicrosoft Research
KeywordsSpiral (railway)VoxelSensitivity (control systems)Contrast (vision)Functional magnetic resonance imagingSampling (signal processing)Compressed sensingArtificial intelligenceMathematicsPattern recognition (psychology)Computer scienceNuclear magnetic resonancePhysicsComputer visionMedicineRadiology

Abstract

fetched live from OpenAlex

PURPOSE: Functional MRI (fMRI) techniques that can provide excellent blood oxygen level dependent contrast, rapid whole brain imaging, and minimal spatial distortion are in demand. This study explored whether fMRI sensitivity can be improved through the use of compressed sensing (CS) reconstruction of variable density spiral fMRI. METHODS: Three different CS-reconstructed 1-shot variable density spirals were explored (corresponding to 28%, 35%, and 46% under-sampling), and compared with conventional 1-shot and 2-shot Archimedean spirals acquired using matched echo time and volume repetition time. fMRI maps were reconstructed with or without CS MRI and sensitivity was compared using identically matched voxels. RESULTS: The results demonstrated that an l1 -norm based CS reconstruction only led to an increase in functional contrast when applied to 28% under-sampled data. A whole brain t-contrast map revealed that 2-shot uniformly sampled spiral and 28% under-sampled spiral data reconstructed with CS yield equivalent sensitivity, even with matched echo time and volume repetition time CONCLUSION: VD spiral exhibits a useful operating range, in the region of 25-30% under-sampling, for which CS reconstruction can be used to increase the sensitivity of fMRI to brain activity. Using CS, VD acquisitions achieve the same sensitivity as 2-shot Archimedean acquisitions, but require only a single shot.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.771
Threshold uncertainty score0.517

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.014
GPT teacher head0.273
Teacher spread0.259 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations37
Published2013
Admission routes2
Has abstractyes

Explore more

Same venueMagnetic Resonance in MedicineSame topicAdvanced MRI Techniques and ApplicationsFrench-language works237,207