MétaCan
← all works

Withdrawn: Comparison of Fit Accuracy between Procera Custom Abutments and Three Implant Systems

2010· article· en· 24 citations· W1911012253 on OpenAlex· 10.1111/j.1708-8208.2010.00311.x

Why is this work in the frame?

A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.

Canadian venueIt was published in a Canadian venue.

No Canadian affiliation. An affiliation-only frame — the usual design — would never have seen this work. It is one of the works that make the case for inverting the frame.

Post-publication record

Nature
Retraction
Reason
Duplication of Content through Error by Journal/Publisher;
Date
4/1/2016 0:00
Flagged by OpenAlex?
Yes

Source: Retraction Watch, joined by DOI. OpenAlex records retraction as is_retracted, a boolean over a state space with at least four values, so it cannot express an expression of concern, a correction or a reinstatement — it reports them as false, which reads as “fine”.

Abstract

BACKGROUND: Although increase of misfit has been reported when associating implant and abutment from different manufacturers, Procera custom abutment has been universally used in clinical practice. PURPOSE: The purpose of this investigation was to compare the vertical gap of zirconia Procera® abutment associated with implants from the same manufacturer (Procera manufacturer) and two other implant systems. MATERIALS AND METHODS: Twenty-four zirconia Procera abutments were produced using computer-assisted design and manufacture and paired with (a) eight MK III, RP 4.1 × 10 mm implants (Nobel Biocare™, Göteborg, Sweden) - GNB group (Nobel Biocare group); (b) eight Try on, 4.1 × 10 mm implants (Sistema de Implantes, São Paulo, Brazil) - ES group (SIN experimental group) ; and (c) eight Master screw, 4.1 × 10 mm implants (Conexão® Sistema de Prótese, São Paulo, Brazil) - EC group (Conexão experimental group). A comparison of the vertical misfit at the implant-abutment interface was taken at six measuring sites on each sample using scanning electron microscopy with a magnification of 408×. One-way analysis of variance was used to test for differences, and Tukey's test was used for pair-wise comparison of groups (α = 0.05). RESULTS: Significant differences relative to average misfit were found when Procera abutments were associated with other implant manufacturers. The ES group and EC group did not differ significantly, but both demonstrated significantly larger average misfit than the GNB group (p = .001). The average misfit was 5.7 µm ± 0.39, 9.53 µm ± 0.52, and 10.62 µm ± 2.16, respectively, for groups GNB, ES, and EC. CONCLUSION: The association of Procera zirconia abutment with other implant systems different from its manufacturer demonstrated significant alteration of vertical misfit at implant-abutment interface.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

The record

Venue
Clinical Implant Dentistry and Related Research
Topic
Dental Implant Techniques and Outcomes
Field
Dentistry
Canadian institutions
Funders
Keywords
ProceraAbutmentImplantDentistryDental AbutmentsOrthodonticsCubic zirconiaMaterials scienceMathematicsDental prosthesisMedicineEngineeringSurgeryComposite materialBiologyStructural engineeringCeramic
Has abstract in OpenAlex
yes