MétaCan
Menu
← Back to cohort

Withdrawn: Comparison of Fit Accuracy between Procera Custom Abutments and Three Implant Systems

2010· article· en· W1911012253 on OpenAlexvenueno aff
Tiago de Morais Alves da Cunha, Roberto Paulo Correia de Araújo, Paulo Vicente Barbosa da Rocha, Rosa Maria Pazos Amoedo

Post-publication record

NatureRetraction
ReasonDuplication of Content through Error by Journal/Publisher;
Date4/1/2016 0:00
Flagged by OpenAlex?Yes

Source: Retraction Watch, joined by DOI. OpenAlex records retraction as is_retracted, a boolean over a state space with at least four values, so it cannot express an expression of concern, a correction or a reinstatement; it reports them as false, which reads as “fine”.

Bibliographic record

VenueClinical Implant Dentistry and Related Research · 2010
Typearticle
Languageen
FieldDentistry
TopicDental Implant Techniques and Outcomes
Canadian institutionsnot available
Fundersnot available
KeywordsProceraAbutmentImplantDentistryDental AbutmentsOrthodonticsCubic zirconiaMaterials scienceMathematicsDental prosthesisMedicineEngineeringSurgeryComposite materialBiologyStructural engineeringCeramic

Abstract

fetched live from OpenAlex

BACKGROUND: Although increase of misfit has been reported when associating implant and abutment from different manufacturers, Procera custom abutment has been universally used in clinical practice. PURPOSE: The purpose of this investigation was to compare the vertical gap of zirconia Procera® abutment associated with implants from the same manufacturer (Procera manufacturer) and two other implant systems. MATERIALS AND METHODS: Twenty-four zirconia Procera abutments were produced using computer-assisted design and manufacture and paired with (a) eight MK III, RP 4.1 × 10 mm implants (Nobel Biocare™, Göteborg, Sweden) - GNB group (Nobel Biocare group); (b) eight Try on, 4.1 × 10 mm implants (Sistema de Implantes, São Paulo, Brazil) - ES group (SIN experimental group) ; and (c) eight Master screw, 4.1 × 10 mm implants (Conexão® Sistema de Prótese, São Paulo, Brazil) - EC group (Conexão experimental group). A comparison of the vertical misfit at the implant-abutment interface was taken at six measuring sites on each sample using scanning electron microscopy with a magnification of 408×. One-way analysis of variance was used to test for differences, and Tukey's test was used for pair-wise comparison of groups (α = 0.05). RESULTS: Significant differences relative to average misfit were found when Procera abutments were associated with other implant manufacturers. The ES group and EC group did not differ significantly, but both demonstrated significantly larger average misfit than the GNB group (p = .001). The average misfit was 5.7 µm ± 0.39, 9.53 µm ± 0.52, and 10.62 µm ± 2.16, respectively, for groups GNB, ES, and EC. CONCLUSION: The association of Procera zirconia abutment with other implant systems different from its manufacturer demonstrated significant alteration of vertical misfit at implant-abutment interface.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.004
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.005
Threshold uncertainty score0.016

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0020.004
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0000.001
Bibliometrics0.0010.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.001
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0050.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.201
GPT teacher head0.516
Teacher spread0.315 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations24
Published2010
Admission routes1
Has abstractyes

Explore more

Same venueClinical Implant Dentistry and Related Research→Same topicDental Implant Techniques and Outcomes→French-language works237,207→