MétaCan
Menu
Back to cohort
Record W1926697053 · doi:10.1002/mrm.25406

In vivo regional ventilation mapping using fluorinated gas MRI with an x‐centric FGRE method

2014· article· en· W1926697053 on OpenAlexafffund
Alexei Ouriadov, Matthew S. Fox, Marcus J. Couch, Tao Li, Iain Ball, Mitchell S. Albert

Bibliographic record

VenueMagnetic Resonance in Medicine · 2014
Typearticle
Languageen
FieldPhysics and Astronomy
TopicAtomic and Subatomic Physics Research
Canadian institutionsLakehead UniversityThunder Bay Regional Research Institute
FundersNatural Sciences and Engineering Research Council of Canada
KeywordsImaging phantomVentilation (architecture)Sulfur hexafluorideScannerLungIn vivoMaterials scienceChemistryNuclear medicinePulse (music)Pulse sequenceInert gasBiomedical engineeringNuclear magnetic resonanceMedicinePhysicsOpticsInternal medicine

Abstract

fetched live from OpenAlex

PURPOSE: Inert fluorinated gas lung MRI is a new and promising alternative to hyperpolarized gas lung MRI; it is less expensive and does not require expensive isotopes/polarizers. The thermally polarized nature of signal obtained from fluorinated gases makes it relatively easy to use for dynamic lung imaging and for obtaining lung ventilation maps. In this study, we propose that the sensitivity and resolution of fluorine-19 (19F) in vivo images can be improved using the x-centric pulse sequence, thereby achieving a short echo time/pulse repetition time. This study is a transitional step for converting to more sustainable gases for lung imaging. METHODS: A 19F-resolution phantom was used to validate the efficiency of performing the x-centric pulse sequence on a clinical scanner. Ventilation maps were obtained in the lungs of five normal rats with a washout approach (adapted from Xe-enhanced computed tomography [Xe-CT] regional ventilation mapping), using mixtures of either sulfur hexafluoride/oxygen or perfluoropropane/oxygen and a two-breath x-centric method. RESULTS: Fractional ventilation (r) values obtained in this study (0.35-0.46 interval) were in good agreement with previously published values for 3He/129Xe. Calculated r gradients agreed well with published gradients obtained in rats with Xe-CT measurements. CONCLUSIONS: These results suggest that fluorinated gases can be reliably used in vivo in dynamic lung studies as an alternative to 3He/129Xe.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.001
Threshold uncertainty score0.003

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.001
Open science0.0000.000
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.029
GPT teacher head0.322
Teacher spread0.293 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations40
Published2014
Admission routes2
Has abstractyes

Explore more

Same venueMagnetic Resonance in MedicineSame topicAtomic and Subatomic Physics ResearchFrench-language works237,207