MétaCan
Menu
Back to cohort
Record W1931572718 · doi:10.1111/cid.12377

Clinical Fitting and Adjustment Time for Implant‐Supported Crowns Comparing Digital and Conventional Workflows

2015· article· en· W1931572718 on OpenAlexvenueno aff
Tim Joda, Joannis Katsoulis, Urs Brägger

Bibliographic record

VenueClinical Implant Dentistry and Related Research · 2015
Typearticle
Languageen
FieldDentistry
TopicDental Implant Techniques and Outcomes
Canadian institutionsnot available
Fundersnot available
KeywordsWorkflowAbutmentCrown (dentistry)ImplantDental AbutmentsDentistryComputer scienceOrthodonticsMedicineEngineeringDatabaseSurgery

Abstract

fetched live from OpenAlex

PURPOSE: The aim of this prospective cohort study was to investigate clinical and laboratory performance of implant-supported reconstructions comparing the digital to the conventional workflow. MATERIALS AND METHODS: Twenty study participants were treated in a cross-over design for single-tooth replacement in posterior sites, each with a customized titanium abutment plus computer-assisted design and computer-assisted manufacturing (CAD/CAM)-zirconia-suprastructure (test: digital workflow; n = 20) and a standardized titanium abutment plus PFM-crown (control: conventional pathway; n = 20). Evaluation of the 40 reconstructions included: 1) feasibility of laboratory cross-mounting of each abutment-crown-connection, and 2) assessment of adaptation time for clinical adjustments of interproximal and occlusal surfaces. Statistical analyses were performed using the exact Wilcoxon rank sum tests. RESULTS: Laboratory cross-mounting was feasible for three reconstruction pairings revealing a 15% vice versa transfer success rate. All implant crowns could be provided successfully within two clinical appointments, independently of the workflow used. The mean clinical adjustment time was significantly lower (p < .001) for test reconstructions from the digital workflow with 2.2 min (standard deviation [SD] ± 2.1) compared with the ones from the conventional pathway with 6.0 min (SD ± 3.9). CONCLUSIONS: The digital workflow was almost threefold more efficient than the established conventional pathway for fixed implant-supported crowns. Clinical fitting could be predictably achieved with no or minor adjustments within the digital process of intraoral scanning plus CAD/CAM technology.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.005
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.002
Threshold uncertainty score0.007

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.005
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0010.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0020.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.229
GPT teacher head0.490
Teacher spread0.261 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations76
Published2015
Admission routes1
Has abstractyes

Explore more

Same venueClinical Implant Dentistry and Related ResearchSame topicDental Implant Techniques and OutcomesFrench-language works237,207