MétaCan
Menu
Back to cohort

An Experimental Comparison of Two Different Clinically Used Implant Designs and Surfaces

2012· article· en· W1956377113 on OpenAlexvenueno aff
Jan Gottlow, Sargon Barkarmo, Lars Sennerby

Bibliographic record

VenueClinical Implant Dentistry and Related Research · 2012
Typearticle
Languageen
FieldDentistry
TopicDental Implant Techniques and Outcomes
Canadian institutionsnot available
Fundersnot available
KeywordsImplantDentistryMaterials scienceComputer scienceOrthodonticsMedicineSurgery

Abstract

fetched live from OpenAlex

BACKGROUND: Various designs of dental implants representing different geometries and surface technologies are commercially available and clinically used in patients. However, data with regard to bone tissue responses and stability for comparison of their biologic performances are rare. PURPOSE: The aim of the present experimental investigation was to compare the bone tissue responses and implant stability between two commonly used dental implants representing different geometries and surface characteristics. MATERIALS AND METHODS: A total of 90 dental implants (4.3 mm in diameter, 10 mm long) with an oxidized surface (Replace Select Tapered, TiUnite, Nobel Biocare AB, Gothenburg, Sweden) (OX) and 90 implants (4.1 mm in diameter, 10 mm total length) with a hydrophilic sand-blasted and acid etched surface (Standard Plus, SLActive, Institut Straumann AG, Basel, Switzerland) (HSBA) were placed in the distal femur (n = 1) and tibia (n = 2) of 30 rabbits. The implants were analyzed with implant stability quotient (ISQ) measurements, removal torque (RTQ) and histomorphometry (bone-implant contact, BIC) after 10 days, 3, and 6 weeks. Moreover, RTQ values were corrected for differences in surface area by calculating the shear strength for each implant. RESULTS: RTQ and ISQ measurements showed an increase with time for both implant types. A significantly higher RTQ value was observed for the HSBA implant at 3 weeks (p = .05). A lower ISQ value was seen for HSBA than for OX implants at placement in the tibia (p < 0.001). HSBA implants showed higher shear strength values than OX implants after 3 weeks (p < .001), and 6 weeks (p < .01). The morphometric measurements showed significantly higher BIC for HSBA implants after 10 days (p < .01), similar values after 3 weeks and significantly higher BIC for OX implants after 6 weeks (p < .001). CONCLUSIONS: Both HSBA and OX implants were well integrated in bone and showed firm and increased stability from placement to after 6 weeks of healing. The HSBA implant showed more BIC after 10 days and the OX implant more BIC after 6 weeks of healing. The HSBA implant showed significantly higher shear strength after 3 and 6 weeks and higher RTQ values after 3 weeks than the OX implant. The results may be due to differences in surface roughness and hydrophilic properties.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.002
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.002
Threshold uncertainty score0.011

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0020.002
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0010.001
Science and technology studies0.0000.001
Scholarly communication0.0000.000
Open science0.0000.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0020.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.308
GPT teacher head0.560
Teacher spread0.252 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations55
Published2012
Admission routes1
Has abstractyes

Explore more

Same venueClinical Implant Dentistry and Related ResearchSame topicDental Implant Techniques and OutcomesFrench-language works237,207