MétaCan
Menu
Back to cohort
Record W1963925263 · doi:10.1115/icone12-49171

An Advanced Ultrasonic Technique for Flow and Void Fraction Measurements of Two-Phase Flow

2004· article· en· W1963925263 on OpenAlexafffund
José Luiz Horácio Faccini, Jian Su, Glenn Harvel, Jo‐Shu Chang

Bibliographic record

Venue12th International Conference on Nuclear Engineering, Volume 3 · 2004
Typearticle
Languageen
FieldEngineering
TopicFlow Measurement and Analysis
Canadian institutionsMcMaster University
FundersNatural Sciences and Engineering Research Council of CanadaInternational Atomic Energy Agency
KeywordsUltrasonic sensorUltrasonic flow meterFlow measurementTwo-phase flowStratified flowFlow visualizationMaterials scienceAcousticsFlow (mathematics)Slug flowPorosityUltrasonic testingMechanicsVoid (composites)Thermal mass flow meterVolumetric flow rateOpen-channel flowMass flow meterTurbulencePhysicsComposite material

Abstract

fetched live from OpenAlex

In this paper, we present a hybrid type contrapropagating transmission ultrasonic technique (CPTU) for flow and time averaging ultrasonic transmission intensity void fraction measurements (TATIU) of air-water two-phase flow, which is tested in the new two-phase flow test section mounted recently onto an existing single phase flow rig at the Nuclear Engineering Institute (IEN)/CNEN, Brazil. The circular pipe test section is made of 51.2 mm stainless steel, followed by a transparent extruded acrylic pipe aimed at flow visualization. The two-phase flow rig operates in several flow regimes: bubbly, smooth stratified, wavy stratified and slug flow. The observed flow patterns are compared with the Mandhane et al.’s experimental and Lightstone et al.’s numerical flow regime map for horizontal two phase flows. These flow patterns will be identified by time averaging transmission intensity ultrasonic techniques which have been developed to meet this particular application. A contrapropagating transmission ultrasonic flowmeter is used to measure the flow rate of liquid phase. A pulse-echo TATIU ultrasonic technique used to measure the void fraction of the horizontal test section assembling at IEN is presented. Other flow parameters can be deduced by processing the signals obtained by the CPTU ultrasonic flowmeter and the pulse-echo generator-receiver (TATIU system).

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.002
Threshold uncertainty score0.004

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0020.001
Science and technology studies0.0000.001
Scholarly communication0.0000.001
Open science0.0010.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.026
GPT teacher head0.274
Teacher spread0.248 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations6
Published2004
Admission routes2
Has abstractyes

Explore more

Same venue12th International Conference on Nuclear Engineering, Volume 3Same topicFlow Measurement and AnalysisFrench-language works237,207