MétaCan
Menu
Back to cohort

Biomechanical Comparison of Intramedullary Nail and Blade Plate Fixation for Tibiotalocalcaneal Arthrodesis

2005· article· en· W1965158269 on OpenAlexaff
Uosife Alfahd, Sandra E. Roth, David Stephen, Cari Whyne

Bibliographic record

VenueJournal of Orthopaedic Trauma · 2005
Typearticle
Languageen
FieldMedicine
TopicFoot and Ankle Surgery
Canadian institutionsSmiths Detection (Canada)Sunnybrook Health Science Centre
Fundersnot available
KeywordsIntramedullary rodMedicineAnkleInternal fixationBiomechanicsFixation (population genetics)Subtalar jointOrthodonticsArthrodesisExternal fixationSurgeryAnatomyExternal fixator

Abstract

fetched live from OpenAlex

OBJECTIVE: Tibiotalocalcaneal arthrodesis is used to manage severe bone loss, arthritis, and/or instability. The goal is to relieve pain through a stable, well-aligned hindfoot and ankle. The purpose of this study was 2-fold: to biomechanically compare 1) initial stability, and 2) the effect of bone density on the stability of intramedullary nail and blade plate fixation in tibiotalocalcaneal arthrodesis. DESIGN: Biomechanical study using anatomic specimens. METHODS: Ankle and subtalar joint capsules were exposed for 7 pairs of fresh-frozen anatomic specimens. One ankle from each pair was instrumented with an interlocked intramedullary nail inserted retrograde across the subtalar and ankle joint while the contralateral hind foot was stabilized with a lateral cannulated blade plate. Specimen stability was tested in plantar/dorsiflexion and inversion/eversion to a maximum bending moment of 12 Nm and in internal/external rotation to a maximum torque of 7 Nm. Physical measurements of bone density were made to determine its effect on stability. MAIN OUTCOME MEASURES: Maximum angular displacement of the constructs in plantarflexion, dorsiflexion, inversion, eversion, internal rotation, and external rotation. RESULTS: No significant differences were observed between the plated and nailed constructs in the 3 loading configurations (Power = 0.77). Only 6 pairs were included in the results because of fixation failures. A small but significant reduction in internal rotation alone of 1.8 degrees was found with the plated compared with the nailed construct (P = 0.045). Reduced stability was associated with lower bone density in torsion and inversion/eversion in the plated constructs (r = 0.67- 0.87) with a similar trend seen in torsion in the nailed constructs (r = 0.5). CONCLUSION: Initial construct stabilities and the effect of reduced bone density were found to be similar between the blade plate and the intramedullary nail in tibiotalocalcaneal arthrodesis, thus implant choice may be based on other clinical factors, such as surgeon preference or soft-tissue status.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.001
Threshold uncertainty score0.004

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.033
GPT teacher head0.313
Teacher spread0.279 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations95
Published2005
Admission routes1
Has abstractyes

Explore more

Same venueJournal of Orthopaedic TraumaSame topicFoot and Ankle SurgeryFrench-language works237,207