Effects of Synchronized Cardiac Assist Device on Cardiac Energetics

2006· article· en· W1965222461 on OpenAlexaffabout
Amir Landesberg, Avshalom Shenhav, Rona Shofty, Eugene Konyukhov, Carmit Levy, O. Lichtenstein, Rafael Beyar, Henk E.D.J. ter Keurs, Giora Landesberg, Marco E. Cabrera, William C. Stanley, Gerald M. Saidel

Bibliographic record

VenueAnnals of the New York Academy of Sciences · 2006
Typearticle
Languageen
FieldEngineering
TopicMechanical Circulatory Support Devices
Canadian institutionsUniversity of Calgary
Fundersnot available
KeywordsEnergeticsCardiologyMedicinePhysicsThermodynamics

Abstract

fetched live from OpenAlex

A novel physiological cardiac assist device (PCAD), the LEV RAM assist device, which is synchronized with the failing heart ejection, was developed to improve the failing heart systolic and diastolic functions and cardiac energetics. The PCAD uses a single short cannula, which is inserted into the beating left ventricle (LV) by means of a specially designed device. Blood is ejected from the PCAD into the LV after the opening of the aortic valve and augments the cardiac stroke work. The same amount of blood is withdrawn from the LV into the PCAD, through the same cannula, during the diastole. The study aims to test the effects of the PCAD on cardiac energetics and coronary blood flow. Adult normal sheep were anesthetized and the heart was exposed by left thoracotomy. Pressures transducers (Millar Instruments, Inc., Houston, TX) were inserted into the LV and aorta. LV volume was measured by sonocrystals (Sonometrics Corp., London, Ontario, Canada) and impedance catheter (CD Lycom, Argonstrat 116 Zoetermeer, 2718 SP The Netherlands). Flowmeters (transonic) measured the cardiac output (CO) and the coronary arteries (left anterior descending (LAD) and circumflex) flows. A thin cannula was inserted into the coronary sinus and the oxygen content of the LV and the coronary sinus were determined (AVOXimeter-1000). Pressure-volume loops, myocardial energetics, and coronary flow were measured. The displaced PCAD volume was 11 mL. Four different levels of assist were studied by changing the frequency of the assist: (1) assist beat after three successive regular beats [1:4], (2) assist every third beat [1:3], (3) alternate assist and normal beat [1:2], and (4) continuous assist [1:1]. Cardiac output (CO) and stroke volume (SV) increased proportionally with increasing frequency of assist. Systolic mechanical efficiency of the PCAD was above 90%. Simultaneously, the PCAD decreased the end-diastolic volume (EDV; diastolic unloading). The PCAD increased coronary flow and decreased cardiac arterial-venous O(2) difference. We conclude that the PCAD efficiently augments CO and stroke work, decreases preload, and decreases the coronary arterial-venous O(2) difference; all these may expedite cardiac reverse remodeling, and promote recovery of function and eventual easy explanation of the device.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.308
Threshold uncertainty score0.504

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.001
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0010.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.032
GPT teacher head0.276
Teacher spread0.244 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations5
Published2006
Admission routes2
Has abstractyes

Explore more

Same venueAnnals of the New York Academy of SciencesSame topicMechanical Circulatory Support DevicesFrench-language works237,207