Rubina Chaudhary, LA Beaupré, DWC Johnston

Bibliographic record

VenueJournal of Bone and Joint Surgery · 2008
Typearticle
Languageen
FieldMedicine
TopicTotal Knee Arthroplasty Outcomes
Canadian institutionsUniversity of AlbertaCapital District Health Authority
Fundersnot available
KeywordsMedicinePosterior cruciate ligamentWOMACRange of motionOsteoarthritisProsthesisConfidence intervalSurgeryArthroplastyKnee replacementRandomized controlled trialQuality of life (healthcare)Physical therapyAnterior cruciate ligamentInternal medicine

Abstract

fetched live from OpenAlex

BACKGROUND: The impact of posterior cruciate ligament-substituting and posterior cruciate ligament-retaining devices on the range of motion of the knee following primary total knee arthroplasty is unclear. The primary objective of our study was to compare the range of motion of the knee over the first two postoperative years between subjects who had received the ligament-substituting design and those who had received the ligament-retaining design. Secondarily, pain, function, and health-related quality of life were compared between the two groups. METHODS: We undertook a prospective randomized study of 100 patients with noninflammatory osteoarthritis who were undergoing primary total knee arthroplasty. Patients were randomized at the time of surgery to receive one of the two study prosthesis designs. They were evaluated preoperatively, at the time of hospital discharge, at three months postoperatively, and at up to two years postoperatively by a physical therapist who was blinded to the group allocation. Active knee flexion and extension, measured with a goniometer, were the primary outcome measures. Self-reported pain, function, and health-related quality of life were measured with the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) and the RAND 36-Item Health Survey (RAND-36). Complications and revision rates were determined through hospital record review and at each patient evaluation. RESULTS: Eighty percent (seventy-eight) of the ninety-eight available patients returned for the final assessment. At two years postoperatively, the mean difference between the groups with regard to knee flexion was 0.03 degrees (95% confidence interval, -5.9 degrees to 6.0 degrees ) and the mean difference in knee extension was 1.0 degrees (95% confidence interval, -0.36 degrees to 2.4 degrees ). Ninety-one (93%) of the ninety-eight available patients completed questionnaires at the time of the final assessment. The two treatment groups had similar pain, function, and quality-of-life scores and complication rates. One subject in the cruciate-retaining group required revision, secondary to a deep joint infection, and one subject in the cruciate-substituting group required manipulation to address poor knee flexion. CONCLUSIONS: Overall, the two treatment groups had a similar range of motion of the knee over the initial two-year postoperative time period. A satisfactory range of motion was achieved by three months postoperatively and was maintained at the final assessment.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.015
Threshold uncertainty score0.553

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.001
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.039
GPT teacher head0.242
Teacher spread0.202 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations119
Published2008
Admission routes2
Has abstractyes

Explore more

Same venueJournal of Bone and Joint SurgerySame topicTotal Knee Arthroplasty OutcomesFrench-language works237,207