Efficacy of Biphasic Transcranial Electric Stimulation in Intraoperative Motor Evoked Potential Monitoring for Cervical Compression Myelopathy
Bibliographic record
Abstract
In Brief Study Design. Retrospective analysis of prospectively collected data from consecutive patients undergoing 2 methods of transcranial electrical motor evoked potential (TCE-MEP) monitoring during cervical spine surgery. Objective. To investigate the efficacy of biphasic transcranial electric stimulation, the deviation rate, amplitude of TCE-MEPs, complications, and sensitivity and specificity of TCE-MEP monitoring were compared between the biphasic and conventional monophasic stimulation methods. Summary of Background Data. With biphasic stimulation, unlike monophasic stimulation, measurement time can be reduced considerably because a single stimulation elicits bilateral responses almost simultaneously. However, no study has yet reported a detailed comparison of the 2 methods. Methods. Examination 1: Amplitude and derivation rate of TCE-MEPs was compared for monophasic and biphasic stimulation in the same 31 patients with cervical compression myelopathy. Examination 2: Sensitivity, specificity, and complications of TCE-MEP monitoring were compared in 200 patients with cervical compression myelopathy who received monophasic or biphasic stimulation (100 patients each) during intraoperative monitoring. Results. Examination 1: Derivation rates of biphasic stimulation in the deltoid, biceps brachii, abductor digiti minimi, and flexor hallucis brevis muscles were the same or higher than for monophasic stimulation. TCE-MEP amplitudes elicited by biphasic stimulation compared with monophasic stimulation were significantly larger in the biceps (paired t, P < 0.0001), but similar in the other 3 muscles. Examination 2: In the biphasic and monophasic stimulation groups, warnings were issued to surgeons in 10 and 11 cases, for a sensitivity of 100% for both groups and specificity of 97.8% and 96.7%, respectively. No complications related to stimulation were observed in any of the 200 patients. Conclusion. Biphasic stimulation had similar or higher derivation rates and equivalent sensitivity and specificity than monophasic stimulation. No complications were observed for either stimulation method. Biphasic stimulation is an effective TCE-MEP monitoring method for cervical spine surgery that may also reduce measurement time. Level of Evidence: 4 Amplitude, derivation rate, complications, sensitivity, and specificity were compared between biphasic and monophasic stimulation in transcranial electrical motor evoked potential (TCE-MEP) monitoring during cervical spine surgery. Biphasic stimulation showed equivalent results to monophasic stimulation. Biphasic stimulation was effective for TCE-MEP monitoring during cervical spine surgery and contributed to reducing measurement time.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame distilled prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.
Codex and Gemma teacher scores by category
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.000 | 0.000 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.000 | 0.000 |
| Bibliometrics | 0.000 | 0.000 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.000 | 0.000 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.000 | 0.000 |
| Insufficient payload (model declined to judge) | 0.000 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one teacher head, not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".