MétaCan
Menu
Back to cohort
Record W1966651623 · doi:10.1097/icl.0b013e318199df54

Multipurpose Disinfecting Solutions and Their Interactions With a Silicone Hydrogel Lens

2009· article· en· W1966651623 on OpenAlex

Why this work is in the frame

A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.

affAt least one author lists a Canadian institution in the pinned OpenAlex snapshot.

Bibliographic record

VenueEye & Contact Lens Science & Clinical Practice · 2009
Typearticle
Languageen
FieldMedicine
TopicOcular Surface and Contact Lens
Canadian institutionsUniversity of Waterloo
Fundersnot available
KeywordsSilicone hydrogelContact lensLens (geology)MedicineOphthalmologyEye careSurgeryOptometryOptics

Abstract

fetched live from OpenAlex

PURPOSE: To assess the compatibility of a new silicone hydrogel lens, asmofilcon A (with four multipurpose disinfecting solutions: OPTIFREE RepleniSH, ReNu MultiPlus, Solo-Care Aqua and MeniCare Soft). Ocular responses and subjective responses were monitored with each lens-care system combination. METHODS: The study was conducted as a prospective, bilateral, clinical trial with a single-masked investigator, and randomized cross-over design with four phases, (one for each care system). Each study phase comprised of two consecutive days of lens wear where the lenses were inserted on day 1 directly from the blister-packs and worn for over 8 hr, then inserted on day 2 after overnight disinfection with one of the study lens care systems. Twenty-five adapted soft contact lens wearers who were able to wear their habitual lenses comfortably for more than 12 hr were recruited. RESULTS: There were statistically significant differences in corneal staining found for all the lens-care systems when comparing the results of day 1 (from the blister pack) with day 2 (following care system use) (P < 0.05). ReNu MultiPlus solution had the highest grade for corneal staining at the 2-hr time point on day 2 which then decreased by 6 hr (P < 0.05). There was no difference between the lens care systems and the rating of subjective comfort over either of the two days. The rating of dryness and burning sensations were only slightly increased at 6 hr for all lens care systems except ReNu MultiPlus where burning was highest on insertion (P < 0.05). CONCLUSION: Corneal staining observed in this study does not seem to have been related to the presence of polyhexamethylene biguanide (0.0001% wv) that was present in three of the four care systems. Only one care system (ReNu MultiPlus) demonstrated an associated level of corneal staining that was statistically significant; however, this was not considered to be of clinical relevance. These results suggest that using this novel surface-treated silicone hydrogel lens may result in less lens and lens care-related interactions.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.003
metaresearch head score (Gemma)0.009
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMetaresearch, Meta-epidemiology (narrow)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.397
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0030.009
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.001
Science and technology studies0.0010.001
Scholarly communication0.0000.003
Open science0.0000.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.059
GPT teacher head0.385
Teacher spread0.326 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it