Bibliographic record
Abstract
Abstract Although axial liquid dispersion has been studied extensively in particulate fluidized beds, no data has been reported previously in a liquid–solid circulating fluidized bed (LSCFb). In this work, the axial liquid dispersions at various radial positions were measured in an LSCFB of 76 mm in diameter and 3.0 m in height using a dual conductivity probe. The results reveal that the axial liquid dispersion is affected not only by the operating conditions but by the radial positions as well. A local axial dispersion model is proposed to describe the axial liquid dispersion at various radial positions. The local axial liquid dispersion coefficients determined by the proposed model are greater at the axis than near the wall region of the riser. This nonuniformity of axial liquid dispersion is believed to be caused by the radial nonuniform distribution of liquid velocity, and bed voidage in the LSCFB can significantly affect the axial liquid dispersion.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame machine prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.
Distilled classifier scores by category (both heads)
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.001 | 0.001 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.001 | 0.000 |
| Bibliometrics | 0.000 | 0.000 |
| Science and technology studies | 0.000 | 0.001 |
| Scholarly communication | 0.001 | 0.001 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.000 | 0.000 |
| Insufficient payload (model declined to judge) | 0.000 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".