Role of the Endothelin System in Secondary Pulmonary Hypertension Related to Air Embolism: Lessons Learned from Testing Four Classes of Endothelin Blockers in a Rat Model
Bibliographic record
Abstract
A rat model of acute pulmonary air embolism (APAE) was developed. These animals had a higher right ventricular systolic pressure (RVSP) (+ 69% at 15-minute peak, and 21-34% at 30-180 minutes), as well as a reduced mean arterial blood pressure (10-20% at 60-180 minutes), heart rate (20-26% at 60-180 minutes) and PaO2 (9-11% at 30-180 minutes) compared with control rats. The role of the endothelin (ET) system, known to be involved in pulmonary hypertension of various etiologies, was investigated by evaluating the effect of the four classes of ET blockers: ET-converting enzyme inhibitor (ECEi) (CGS 35066), selective endothelin-A receptor antagonist (ETA-Ra) (Atrasentan, ABT-627), endothelin-B receptor antagonist (ETB-Ra) (A-192621) or mixed endothelin-A/endothelin-B receptor antagonist (ETA/B-Ra) (A-182086) in this animal model. All four were effective, to various degrees, at reducing the APAE-induced rise in RVSP. The relative efficacy of those compounds in reducing the acute elevation (15 minutes) of RVSP was ECEi >or= ETA/B-Ra >> ETA-Ra = ETB-Ra. The sustained elevation (30-180 minutes) of RVSP was totally abolished by ECEi and attenuated by other ET blockers with a relative efficacy of ETA-Ra > ETA/B-Ra >or= ETB-Ra. ET receptor antagonists did not affect right ventricular basal tone (control rats) whereas ECEi reduced it by up to 12% after 2 hours. The APAE reduction in mean arterial blood pressure was unaffected by ETARa, was completely normalized by ETB-Ra, but was further reduced by either ETA/B-Ra or ECEi. The basal mean arterial blood pressure in control rats was unaffected by ETA-Ra, was elevated by ETB-Ra, but was depressed by ETA/B-Ra and ECEi. All ET blockers maintained normal oxygen saturation in APAE. These results support a role for ETs in rat APAE, since ET blockers can attenuate the cardiopulmonary deterioration and blood gas exchange. However, modulation of the central hemodynamic profile is more complex and may limit the usefulness of some ET blockers.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame distilled prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.
Codex and Gemma teacher scores by category
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.002 | 0.000 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.002 | 0.001 |
| Bibliometrics | 0.001 | 0.001 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.000 | 0.000 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.000 | 0.001 |
| Insufficient payload (model declined to judge) | 0.000 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one teacher head, not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".