MétaCan
Menu
Back to cohort

The Effect of Interbody Cage Positioning on Lumbosacral Vertebral Endplate Failure in Compression

2005· article· en· W1968273825 on OpenAlexaff
Robert D. Labrom, Juay-Seng Tan, Christopher W. Reilly, Stephen J. Tredwell, Charles G. Fisher, Thomas R. Oxland

Bibliographic record

VenueSpine · 2005
Typearticle
Languageen
FieldMedicine
TopicSpine and Intervertebral Disc Pathology
Canadian institutionsVancouver Hospital and Health Sciences CentreBC Children's HospitalVancouver Coastal Health Research InstituteUniversity of British Columbia
Fundersnot available
KeywordsMedicineLumbosacral jointCageCompression (physics)Spinal fusionAnatomySurgeryStructural engineeringComposite material

Abstract

fetched live from OpenAlex

In Brief Study Design. A biomechanical investigation using a human cadaver, multisegmental lumbosacral spine model. Objectives. To determine if 2 small, posterolaterally positioned titanium mesh interbody cages would provide superior construct strength and stiffness in compression compared to central cage placement. In addition, determine construct stiffness with interbody cages as opposed to an intact spine and assess the effect of bone mineral density (BMD). Summary of Background Data. Previous work has shown that the posterolateral corners of the lumbosacral endplates are stronger than the anterior and central regions. Information to suggest appropriate interbody cage positioning to avoid subsidence into adjacent vertebrae would be valuable for spine surgeons and implant designers. Methods. A total of 27 functional spinal units from L3 to S1 were dual x-ray absorptiometry scanned for BMD, instrumented with pedicle screw systems, and tested to failure in compression with titanium mesh interbody cages placed in 1 of 3 positions: 2 small posterolateral, 2 small central, or 1 large central. Analysis of covariance was conducted to compare failure load and stiffness across the different cage configurations. Repeated measures analysis of variance was used to analyze stiffness between functional spinal units with intact disc, discectomy, or interbody cages. Failure load was correlated against BMD. Results. Of the 3 placement patterns, 2 small titanium mesh cages in the posterolateral corners had 20% higher failure loads, although the difference was not significant (P = 0.20). Stiffness in compression for the 3 cage positions was not significantly different (P = 0.82). All intact discs with posterior instrumentation were significantly stiffer than any of the cage patterns (P = 0.0001). BMD of the vertebrae significantly correlated with failure loads (P = 0.007). Conclusions. The placement of 2 small interbody cages posterolaterally tended to result in higher failure loads than central cage placement, although the results were not statistically significant. It is noteworthy that cage placement in any position resulted in a less stiff construct in compression than with an intact disc. Compression tests to failure conducted on 27 functional spinal units (L3−S1) with posterior spinal instrumentation tended to result in higher failure loads with 2 smaller titanium mesh interbody cages placed in the posterolateral corners of the endplates, although the results were not significant. It was noteworthy that cage placement in any position resulted in a less stiff construct in compression than with an intact disc.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.616
Threshold uncertainty score0.295

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.006
GPT teacher head0.287
Teacher spread0.281 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations47
Published2005
Admission routes1
Has abstractyes

Explore more

Same venueSpineSame topicSpine and Intervertebral Disc PathologyFrench-language works237,207