MétaCan
Menu
Back to cohort
Record W1969082035 · doi:10.1016/j.jcv.2013.08.008

Comparative evaluation of the Bio-Rad Geenius HIV-1/2 Confirmatory Assay and the Bio-Rad Multispot HIV-1/2 Rapid Test as an alternative differentiation assay for CLSI M53 algorithm-I

2013· article· en· W1969082035 on OpenAlex

Why this work is in the frame

A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.

affAt least one author lists a Canadian institution in the pinned OpenAlex snapshot.
fundA Canadian funder is recorded on the work.
aboutThe title or abstract carries a Canadian signal from the geographic lexicon.

Bibliographic record

VenueJournal of Clinical Virology · 2013
Typearticle
Languageen
FieldImmunology and Microbiology
TopicHIV Research and Treatment
Canadian institutionsCapital District Health AuthorityProvincial Laboratory of Public HealthSaskatchewan Disease Control LaboratoryPublic Health Agency of Canada
FundersPublic Health Agency of Canada
KeywordsHuman immunodeficiency virus (HIV)MedicineVirology

Abstract

fetched live from OpenAlex

INTRODUCTION: The CLSI-M53-A, Criteria for Laboratory Testing and Diagnosis of Human Immunodeficiency Virus (HIV) Infection; Approved Guideline includes an algorithm in which samples that are reactive on a 4th generation EIA screen proceed to a supplemental assay that is able to confirm and differentiate between antibodies to HIV-1 and HIV-2. The recently CE-marked Bio-Rad Geenius HIV-1/2 Confirmatory Assay was evaluated as an alternative to the FDA-approved Bio-Rad Multispot HIV-1/HIV-2 Rapid Test which has been previously validated for use in this new algorithm. METHODS: This study used reference samples submitted to the Canadian - NLHRS and samples from commercial sources. Data was tabulated in 2×2 tables for statistical analysis; sensitivity, specificity, predictive values, kappa and likelihood ratios. RESULTS: The overall performance of the Geenius and Multispot was very high; sensitivity (100%, 100%), specificity (96.3%, 99.1%), positive (45.3, 181) and negative (0, 0) likelihood ratios respectively, high kappa (0.96) and low bias index (0.0068). The ability to differentiate HIV-1 (99.2%, 100%) and HIV-2 (98.1%, 98.1%) Ab was also very high. CONCLUSION: The Bio-Rad Geenius HIV-1/2 Confirmatory Assay is a suitable alternative to the validated Multispot for use in the second stage of CLSI M53 algorithm-I. The Geenius has additional features including traceability and sample and cassette barcoding that improve the quality management/assurance of HIV testing. It is anticipated that the CLSI M53 guideline and assays such as the Geenius will reduce the number of indeterminate test results previously associated with the HIV-1 WB and improve the ability to differentiate HIV-2 infections.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.007
metaresearch head score (Gemma)0.003
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.607
Threshold uncertainty score0.623

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0070.003
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.002
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.078
GPT teacher head0.401
Teacher spread0.323 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it