MétaCan
Menu
Back to cohort
Record W1970829662 · doi:10.1118/1.4735863

TU‐A‐BRB‐06: Characterization of a Commercial Photodiode Based Plastic Scintillation Detector Prototype

2012· article· en· W1970829662 on OpenAlexaff
Landon S. Wootton, David M. Klein, C Bonde, Elizabeth Adams, Daniel Schmidt, Luc Beaulieu, Sam Beddar

Bibliographic record

VenueMedical Physics · 2012
Typearticle
Languageen
FieldMedicine
TopicRadiation Dose and Imaging
Canadian institutionsCentre hospitalier universitaire de Québec
Fundersnot available
KeywordsDetectorPhotodiodeReproducibilityIonization chamberScintillationOpticsDosimetryScintillatorPhotonDose profileMaterials sciencePhysicsOptoelectronicsImaging phantomNuclear medicineIonizationChemistryMedicine

Abstract

fetched live from OpenAlex

Purpose: The purpose of this work is to characterize a commercial plastic scintillation detector (PSD) prototype that uses a photodiode to convert scintillation light to an electronic signal that can be measured with an electrometer. We tested the reproducibility of the detector as well as its accuracy. Methods: The detector consists of 3 mm of scintillating fiber 1 mm in diameter connected to a photodiode via approximately 2 m of optical fiber. We tested the reproducibility of the detector by making daily measurements in a cobalt beam. We then verified the accuracy of the detector by measuring percent depth dose (PDD) curves on a linac for two photon and electron energies. The measurements were compared to commissioning data (measured with an ionization chamber) to quantify the accuracy of the detector. Results: Over the course often days the mean dose the detector measured varied by 0.16% (1 standard deviation). The individual measurements on specific days varied as much as 0.27% and as little as 0.09%. PDD curves obtained with the detector differed from commissioning data by less than 0.6% for both photon energies. For both electron energies, the detector results differed from commissioning data less than 3% before the steep dose gradient towards the end of the electron range. In the dose falloff the difference was as great as 8% (likely due to positioning errors). Conclusions: This new photodiode based PSD exhibited a very high level of reproducibility both in terms of individual measurements and average measurements on different days. Depth dose curves measured with the PSD in photon and electron beams demonstrated excellent agreement with machine commissioning data, validating the accuracy of this detector as well confirming that it is an energy independent detector. This work was partly supported by an NIH/NCI SBIR phase I grant (1R43CA153824‐01) in collaboration with Standard Imaging Inc.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.003
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Methods · Consensus signal: none
Teacher disagreement score0.002
Threshold uncertainty score0.008

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.003
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.001
Science and technology studies0.0000.000
Scholarly communication0.0010.001
Open science0.0020.000
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0020.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.019
GPT teacher head0.277
Teacher spread0.258 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreMethods

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2012
Admission routes1
Has abstractyes

Explore more

Same venueMedical PhysicsSame topicRadiation Dose and ImagingFrench-language works237,207