MétaCan
Menu
Back to cohort
Record W1971226619 · doi:10.1109/tuffc.2010.1707

Difference frequency magneto-acousto-electrical tomography (DF-MAET): application of ultrasound-induced radiation force to imaging electrical current density

2010· article· en· W1971226619 on OpenAlexaff
Elena Renzhiglova, Vitaliy Ivantsiv, Yuan Xu

Bibliographic record

VenueIEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · 2010
Typearticle
Languageen
FieldEngineering
TopicElectrical and Bioimpedance Tomography
Canadian institutionsToronto Metropolitan University
Fundersnot available
KeywordsUltrasoundMagnetoCurrent (fluid)Electrical currentTomographyRadiationCurrent densityMaterials scienceElectric currentAcousticsPhysicsNuclear magnetic resonanceOpticsElectrical engineeringVoltageEngineering

Abstract

fetched live from OpenAlex

Magneto-acousto-electrical tomography (MAET) is a potential imaging modality which can provide high-spatial-resolution images of the impedance of conductive media. In MAET, the impedance is reconstructed from the mapped current density distribution J(ab)(r) that would exist in a sample if a current/voltage source were to be applied through measurement electrodes a and b. To map J(ab)(r) without applying a current/voltage source, the sample is placed in a static magnetic field and a focused ultrasonic pulse is directed to a point r to generate a point-like dipole source via the Lorentz force mechanism. The MAET voltage U(ab), which is directly proportional to J(ab)(r), is measured through electrodes a and b for each scanning point. To reconstruct the electrical impedance, we need to map the current density distribution at every point inside the sample. However, with the MAET experimental setup reported in our previous paper on MAET, the MAET signal from a homogenous interior of the sample is undetectable because of the spatially-oscillating nature of the ultrasound field inside the sample. In this paper, we propose to use dual-frequency ultrasound to generate the MAET signal at the difference frequency through the ultrasound radiation force mechanism. The dynamic radiation force causes vibrations inside the sample (and consequently, generates the electric field) with a wavelength much larger than the dimension of the sample along the transducer's axis. Therefore, the MAET signal caused by the radiation force will not be canceled out. We create a dynamic radiation force by applying an amplitude-modulated signal with a modulation frequency fm of several kilohertz and a carrier frequency f(0) of 2.25 MHz to drive the transducer. The dependence of the DF-MAET signal in experiments on the modulation frequency and on the density of the sample agrees with the prediction based on the radiation force mechanism. The spatial resolution of DF-MAET is also studied to verify the radiation force mechanism. Finally, we will prove that the parametric effect in the coupling oil is not a significant source of the DF-MAET signal by imaging a sample at different distances from the transducer. Potential improvements to the present DF-MAET experimental configuration are also discussed.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMeta-epidemiology (narrow)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.609
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0010.003
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.002
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.004
GPT teacher head0.209
Teacher spread0.204 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations33
Published2010
Admission routes1
Has abstractyes

Explore more

Same venueIEEE Transactions on Ultrasonics Ferroelectrics and Frequency ControlSame topicElectrical and Bioimpedance TomographyFrench-language works237,207