MétaCan
Menu
Back to cohort
Record W1971302485 · doi:10.1107/s0909049502017739

Interferometer-controlled scanning transmission X-ray microscopes at the Advanced Light Source

2003· article· en· W1971302485 on OpenAlexafffund
A. L. D. Kilcoyne, T. Tyliszczak, W. F. Steele, Sirine C. Fakra, Peter B. Hitchcock, Keith D. Franck, Erik Anderson, B. Harteneck, E. G. Rightor, G. E. Mitchell, Adam P. Hitchcock, Luyi Yang, Tony Warwick, Harald Ade

Bibliographic record

VenueJournal of Synchrotron Radiation · 2003
Typearticle
Languageen
FieldPhysics and Astronomy
TopicAdvanced X-ray Imaging Techniques
Canadian institutionsMcMaster UniversityBrockhouse Institute for Materials Research
FundersNatural Sciences and Engineering Research Council of CanadaNorth Carolina State UniversityDivision of Materials ResearchU.S. Department of EnergyNational Science Foundation
KeywordsBeamlineUndulatorOpticsMicroscopeAdvanced Photon SourceZone platePhysicsInterferometryMaterials scienceDiffractionBeam (structure)

Abstract

fetched live from OpenAlex

Two new soft X-ray scanning transmission microscopes located at the Advanced Light Source (ALS) have been designed, built and commissioned. Interferometer control implemented in both microscopes allows the precise measurement of the transverse position of the zone plate relative to the sample. Long-term positional stability and compensation for transverse displacement during translations of the zone plate have been achieved. The interferometer also provides low-distortion orthogonal x, y imaging. Two different control systems have been developed: a digital control system using standard VXI components at beamline 7.0, and a custom feedback system based on PC AT boards at beamline 5.3.2. Both microscopes are diffraction limited with the resolution set by the quality of the zone plates. Periodic features with 30 nm half period can be resolved with a zone plate that has a 40 nm outermost zone width. One microscope is operating at an undulator beamline (7.0), while the other is operating at a novel dedicated bending-magnet beamline (5.3.2), which is designed specifically to illuminate the microscope. The undulator beamline provides count rates of the order of tens of MHz at high-energy resolution with photon energies of up to about 1000 eV. Although the brightness of a bending-magnet source is about four orders of magnitude smaller than that of an undulator source, photon statistics limited operation with intensities in excess of 3 MHz has been achieved at high energy resolution and high spatial resolution. The design and performance of these microscopes are described.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.003
Threshold uncertainty score0.011

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0020.001
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0010.001
Science and technology studies0.0000.001
Scholarly communication0.0010.001
Open science0.0020.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0030.002

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.004
GPT teacher head0.249
Teacher spread0.245 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations712
Published2003
Admission routes2
Has abstractyes

Explore more

Same venueJournal of Synchrotron RadiationSame topicAdvanced X-ray Imaging TechniquesFrench-language works237,207