MétaCan
Menu
Back to cohort
Record W1971461453 · doi:10.1115/1.4007932

Design and Manufacturing of Embedded Air-Muscles for a Magnetic Resonance Imaging Compatible Prostate Cancer Binary Manipulator

2012· article· en· W1971461453 on OpenAlexafffund
Geneviève Miron, Alexandre Girard, Jean‐Sébastien Plante, Martin Lepage

Bibliographic record

VenueJournal of Mechanical Design · 2012
Typearticle
Languageen
FieldEngineering
TopicProsthetics and Rehabilitation Robotics
Canadian institutionsUniversité de Sherbrooke
FundersNatural Sciences and Engineering Research Council of Canada
KeywordsMagnetic resonance imagingComputer scienceRobotSimulationBiomedical engineeringArtificial intelligenceEngineering

Abstract

fetched live from OpenAlex

Magnetic resonance imaging (MRI) compatible robots can assist physicians with the insertion of biopsy needles and needle-like therapeutic instruments directly into millimeter-size tumors, using MR images as feedback. However, MRI systems present a challenging environment with high magnetic fields and limited space, making the development of MRI-compatible robots complex. This paper presents an MRI-compatible pneumatic actuation technology consisting of molded polymer structures with embedded air-muscles operated in a binary fashion. Along with its good positioning accuracy, the technology presents advantages of compactness, perfect MRI-compatibility, simplicity and low cost. Here, we specifically report the design and validation of a transperineal prostate cancer manipulator prototype that has 20 embedded air-muscles distributed in four star-like polymer structures. These compliant structures are made of silicone elastomer, using lost-core injection molding. Low motion hysteresis and good precision are achieved by designing molded joints that eliminate sliding surfaces. An effective design method for such embedded polymer air-muscles is proposed, using a manipulator model and four air-muscle design models: geometrical, finite elements, uniaxial analytic, and experimental. Binary control of each air-muscle ensures stability and accuracy with minimized costs and complexity. The prototype is found MRI-compatible with no observable effects on the signal-to-noise ratio and, with appropriate image feedback, is found to reach targets with precision and accuracy under 0.5 mm. The embedded approach reveals to be a key feature since it reduces hysteresis errors by a factor of ≈7 compared to a previous nonembedded version of the manipulator. The successful validation of this binary manipulator opens the door to a new design paradigm for low cost and highly capable pneumatic robots.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: Simulation or modeling
GenreCandidate signal: Methods · Consensus signal: none
Teacher disagreement score0.639
Threshold uncertainty score0.448

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.024
GPT teacher head0.252
Teacher spread0.228 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designSimulation or modeling
Domainnot available
GenreMethods

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations14
Published2012
Admission routes2
Has abstractyes

Explore more

Same venueJournal of Mechanical DesignSame topicProsthetics and Rehabilitation RoboticsFrench-language works237,207