Radial P32 ion implantation using a coaxial plasma reactor: Activity imaging and numerical integration

2004· article· en· W1971591297 on OpenAlexafffund
Marc‐André Fortin, V. Dufresne, R.W. Paynter, A. Sarkissian, B.L. Stansfield

Bibliographic record

VenueReview of Scientific Instruments · 2004
Typearticle
Languageen
FieldEngineering
TopicMetal and Thin Film Mechanics
Canadian institutionsPlasmionique (Canada)Institut National de la Recherche Scientifique
FundersNatural Sciences and Engineering Research Council of Canada
KeywordsIon implantationCoaxialMaterials sciencePlasmaSputteringIonizationIonBiomedical engineeringRadiochemistryChemistryNanotechnologyNuclear physicsComputer sciencePhysicsThin filmMedicine

Abstract

fetched live from OpenAlex

Beta-emitting biomedical implants are currently employed in angioplasty, in the treatment of certain types of cancers, and in the embolization of aneurysms with platinum coils. Radioisotopes such as P32 can be implanted using plasma-based ion implantation (PBII). In this article, we describe a reactor that was developed to implant radioisotopes into cylindrical metallic objects. The plasma first ionizes radioisotopes sputtered from a target, and then acts as the source of particles to be implanted into the biased biomedical device. The plasma therefore plays a major role in the ionization/implantation process. Following a sequence of implantation tests, the liners protecting the interior walls of the reactor were changed and the radioactivity on them measured. This study demonstrates that the radioactive deposits on these protective liners, adequately imaged by radiography, can indicate the distribution of the radioisotopes that are not implanted. The resulting maps give unique information about the activity distribution, which is influenced by the sputtering of the P32-containing fragments, their ionization in the plasma, and also by the subsequent ion transport mechanisms. Such information can be interpreted and used to significantly improve the efficiency of the implantation procedure. Using a surface barrier detector, a comparative study established a relationship between the gray scale of radiographs of the liners, and activity measurements. An integration process allows the quantification of the activities on the walls and components of the reactor. Finally, the resulting integral of the P32 activity is correlated to the sum of the radioactivity amounts that were sputtered from radioactive targets inside the implanter before the dismantling procedure. This balance addresses the issue of security regarding PBII technology and confirms the confinement of the radioactivity inside the chamber.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.533
Threshold uncertainty score0.419

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.021
GPT teacher head0.255
Teacher spread0.234 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations6
Published2004
Admission routes2
Has abstractyes

Explore more

Same venueReview of Scientific InstrumentsSame topicMetal and Thin Film MechanicsFrench-language works237,207